69
5
Settings
5. Settings
Digitax SF
Instruction Manual
5. Parameters
5.
Parameters
No. 224.2
Deceleration stop:
Enable
Switch (upon
AC Supply
loss)
Settings
Default
Characteristics
0, 1
1
Function
Use
Enable/Disable deceleration stop when
an AC supply loss condition occurs
.
Settings
Selection
0
Disable
1
Enable
Related To
No. 228.0
No. 224.3
Deceleration stop:
DBRK output after stopping
(upon Servo Off)
Settings
Default
Characteristics
0, 1
1
Function
Use
Select Stop State when the servo is off
Settings
Description
0
Coast to stop
1
Emergency stop
brake
Prerequisite
No. 224.0, No.232.1
Settings
Default
Characteristics
0, 1
0
Function
Use
Set whether a warning
is
to be output or not in case of E-stop input.
Settings
Warning output
0
Disable
1
Enable
No. 225.1
Emergency stop:
Warning output timing
Settings
Default
Characteristics
0, 1
0
Function
Use
Specify when to output
a
warning in case of E-stop input.
Settings
Warning output timing
0
After the motor makes a deceleration stop
1
Immediately after the warning occurs
Prerequisite
Emergency stop: Warning output switch (225.0) = 1 (Output warning)
No. 225.2
Quick stop:
Smoothing filter -
Enable
Switch
Settings
Default
Characteristics
0, 1
0
Function
Use
Enable/Disable the Velocity Command smoothing filter at the time of a quick stop.
This filter suppresses vibration caused by drastic velocity change.
Settings
Velocity Command smoothing filter
0
Disable
1
Enable
Prerequisite
No. 229.0
-
-
-
-
-
Emergency stop:
Warning output
enable switch
No. 225.0
Содержание Control Techniques Digitax-SF DA21223
Страница 1: ...Instruction Manual AC SERVO MOTOR and SERVO DRIVE Series Digitax SF Part Number 0478 0606 01 Issue 1 ...
Страница 6: ...6 MEMO Digitax SF Instruction Manual ...
Страница 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Страница 138: ...5 5 Settings 1 Overview 2 3 3 4 4 5 6 7 17 19 20 21 22 23 24 27 28 30 34 39 52 64 68 76 82 84 88 96 98 ...
Страница 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Страница 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Страница 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Страница 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...
Страница 386: ...Digitax SF Instruction Manual 0478 0606 01 ...