43
5
Settings
5. Settings
Digitax SF
Instruction Manual
5. Parameters
5.
Parameters
No. 67.0
Drive
limit switch input:
Setup
Settings
Default
Characteristics
0 to 3
0
Function
Use
By installing sensors at the ends of linear motion, you can restrict the drive
within
the motion range.
When “enable” is selected for this parameter, starting the motor will be blocked by I/O input ON.
Settings
CW Drive
limit switch input
CCW Drive
limit switch input
0
Disable
Disable
1
Enable
Disable
2
Disable
Enable
3
Enable
Enable
Related To
No.67.1, No. 67.2, No. 67.3
No. 67.1
Drive
limit switch input:
Deceleration
method
Settings
Default
Characteristics
0 to 2
1
No. 67.2
Drive
limit switch input
:
Idling
status
0, 1
0
Function
Use
Select the deceleration method upon drive
limit switch input
and specify the
idling state after the motor stopped its motion.
Use one of the following four combinations.
Possible
Combinations
Deceleration method
( 67.1)
Idling status
( 67.2)
1
0:
Coast to stop
0:
Coast to stop
2
1: Short Brake
3
2: Quick Stop
1: Zero Clamp
4
0:
Coast to stop
Prerequisite
Drive
limit switch input
: Setup (67.0)
= 1, 2 or 3 (Enable)
Related To
No.67.0, No. 67.3
No. 67.3
Drive
limit switch input:
Retaining position
error
counter
Settings
Default
Characteristics
0, 1
0
Function
Use
Motor's stopping upon drive
limit switch
input
results in position
error
from the input pulse.
Use this parameter to select either keep or clear that position
error
.
Settings
Position
Error
Counter
0
Keep
1
Clear
Related To
No.67.0, No.67.1, No. 67.2
Содержание Control Techniques Digitax-SF DA21223
Страница 1: ...Instruction Manual AC SERVO MOTOR and SERVO DRIVE Series Digitax SF Part Number 0478 0606 01 Issue 1 ...
Страница 6: ...6 MEMO Digitax SF Instruction Manual ...
Страница 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Страница 138: ...5 5 Settings 1 Overview 2 3 3 4 4 5 6 7 17 19 20 21 22 23 24 27 28 30 34 39 52 64 68 76 82 84 88 96 98 ...
Страница 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Страница 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Страница 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Страница 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...
Страница 386: ...Digitax SF Instruction Manual 0478 0606 01 ...