3. Preparation
Digitax SF
Instruction Manual
3. Timing Diagrams
Alarm Occurs
*1) The motor will stop per Deceleration Stop Method (No.224.0) as follows.
2 (quick stop) or 1 (short brake)
: the motor decelerates and stops by short brake.
0 (
Coast to stop
)
: no brake.
*2)
Deceleration Stop Status
ends when deceleration stop conditions set by the parameters (No.224.1, No.226.0, and No.227.0) are met.
*3) Timing of
MBRK
turning OFF
If Deceleration Stop Method (No.224.0) = 2 (quick stop) or 1 (short brake),
MBRK
turns OFF when one of the following conditions is met.
1)
Deceleration Stop Status
turns OFF
2)
Motor Rotational Speed
drops to the value specified by the parameter No.227.0 or below.
If Deceleration Stop Method (No.224.0) = 0 (no brake),
MBRK turns OFF when
Motor Excitation Status
turns OFF.
If any of the following alarms occurs,
MBRK
turns OFF when the internal error status becomes
ERROR
.
a) Encoder related errors
b) Control Power voltage drop error
c) Errors related to Inverter output part
d) Overvoltage error
If any alarm except above four occurs, the motion pattern will be exactly as this timing diagram suggests.
*4) Deceleration Stop behaves as follows depending on the error type:
a)
Encoder related errors: Deceleration Stop per [Deceleration stop operating time (Parameter No. 226.0)]
b)
Control Power voltage drop error: Deceleration Stop per [Deceleration stop (upon control power failure) Operating time (No.228.0)]
c)
Errors related to Inverter output part:
Coast to stop
*5) In case of the following alarms,
Servo Status
will remain ON until
Deceleration Stop Status
turns OFF.
a)
Encoder related errors
b)
Control power voltage drop error
Signal Description
Name
Timing Diagrams
(Output Transistor Status, I/O Input Status, and Internal Status)
AC Supply
Power
L1L2
or
L1L2L3
Servo Ready
SRDY
Servo On
SVON
Internal Error Status
-
Motor Excitation Status
-
Deceleration Stop Status
-
Servo Status
SERVO
Motor
Brake Release
MBRK
Alarm Status
ALM
Motor Rotational Speed
-
The value of the parameterno.227.0
Содержание Control Techniques Digitax-SF DA21223
Страница 1: ...Instruction Manual AC SERVO MOTOR and SERVO DRIVE Series Digitax SF Part Number 0478 0606 01 Issue 1 ...
Страница 6: ...6 MEMO Digitax SF Instruction Manual ...
Страница 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Страница 138: ...5 5 Settings 1 Overview 2 3 3 4 4 5 6 7 17 19 20 21 22 23 24 27 28 30 34 39 52 64 68 76 82 84 88 96 98 ...
Страница 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Страница 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Страница 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Страница 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...
Страница 386: ...Digitax SF Instruction Manual 0478 0606 01 ...