83
5
Settings
5. Settings
Digitax SF
Instruction Manual
5. Parameters
5.
Parameters
No. 302.2
Analog torque:
Offset tuning method
Settings
Default
Characteristics
0, 1
1
Function
Use
Specify the offset tuning method for Analog Velocity command.
Settings
Tuning Method
Description
0
Auto Tuning
Automatically adjust the offset value such that torque command=0 %
at the input voltage at the time of servo on.
1
Manual Tuning
Manually adjust the offset value such that torque command=0 %
at 0 V input voltage.
No. 305.0
Voltage
dip
Detection:
Delay time
Range
Default
Characteristics
20 to 50,000
80
[ms]
Function
Use
Set the delay time to
the required
voltage
dip detection time
of the
AC
supply.
Remark
Detection of a voltage
dip
will result in Alarm No.15.
Set this parameter suitable to your operating conditions.
-
-
Содержание Control Techniques Digitax-SF DA21223
Страница 1: ...Instruction Manual AC SERVO MOTOR and SERVO DRIVE Series Digitax SF Part Number 0478 0606 01 Issue 1 ...
Страница 6: ...6 MEMO Digitax SF Instruction Manual ...
Страница 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Страница 138: ...5 5 Settings 1 Overview 2 3 3 4 4 5 6 7 17 19 20 21 22 23 24 27 28 30 34 39 52 64 68 76 82 84 88 96 98 ...
Страница 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Страница 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Страница 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Страница 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...
Страница 386: ...Digitax SF Instruction Manual 0478 0606 01 ...