17
4
Connection
Digitax SF
Instruction Manual
2
.
Position Control Mode
4.
Connection
s
2.
Position Control Mode
1: 24 V
24 V
GND
24 V
G24 V
2: G24 V
3: COM+
4: SVON
5: RESET/PCLR
6: PCSTART1
7: PCSEL1
9: PCSEL3
10: HOME
11: TLSEL1
12: COM-
13: PM1
14: PM2
15: PM3
17:
MEND/T-LIMIT
18: OCZ
19: SERVO+
20: SERVO-
21: ALM+
22: ALM-
FG
36: OUT_A
37: /OUT_A
38: OUT_B
39: /OUT_B
40: OUT_Z
41: /OUT_Z
43: 485
44: /485
45: SG
42: SG
SG
Control power supply 24 V input
Control power supply GND
I/O power supply 24 V input
INPUT
䚷
Servo ON
INPUT Alarm reset
/
Position error
counter clear
INPUT
䚷
Motion start
INPUT
䚷
Point table No.
selection 3
INPUT
䚷
Homing start
INPUT
䚷
Torque limit selection
I/O power supply GND
OUTPUT
䚷
Point table No.
bit code 1
OUTPUT
䚷
Point table No.
bit code 3
OUTPUT
䚷
Point table No.
bit code 2
OUTPUT
䚷
Motion complete
/Under torque limit
㻻㼁㼀㻼㼁㼀䚷㻱㼚㼏㼛㼐㼑㼞㻌㼆㻙㼜㼔㼍㼟㼑
䠄
open-collector
䠅
OUTPUT
䚷
Servo-Ready+
OUTPUT
䚷
Servo-Ready-
OUTPUT
⅙
Alarm State+
OUTPUT
䚷
Alarm State-
A-phase
output
B-phase
output
Z-phase
output
RS-422 output
Twisted Pair Cable
Frame
Encoder Signal Output
Control Power
Shielded
㻖
3
㻖
1
㻖
1
㻖
1
㻖
1
㻖
2
㻖
6
㻖
4
㻖
5
Servo
Drive
4.7 k
Ω
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
MAX 50 mA
SG
8: PCSEL2
16: HEND
INPUT
䚷
Point table No.
selection 1
INPUT
䚷
Point table No.
selection 2
OUTPUT
䚷
Homing
complete
MAX 50 mA
RS-485
Host Controller
SG
㻖
5
㻖
4
*1) Control power (24V, G24V) and power for I/O (COM+, COM-) must share one common power supply.
*2) When driving a load containing inductance
(
component such as
a
relay
)
connect a protection circuit (diode).
The motor brake cannot be driven directly. Be sure to use a circuit that interfaces with a diode built-in type relay.
Page 46 Connection to general-purpose output signals
*3) The output circuit configuration is an open collector Darlington transistor output. Connects to relays and optical isolators.
Note that when the transistor is on, connector-emitter voltage VCE (SAT) is approximately 1V;
a standard TTL IC does not satisfy VIL and cannot be connected directly.
*4) Be sure to connect a termination resistor of approximately 220 Ω .
*5) Make the connection to the communication IC signal ground of the host controller that
the drive
encoder output signals
are connecting to. Connecting signal ground SG to control power GND may result in malfunction.
*6) If Z-phase pulse width is too small to be measured accurately by the host controller, decrease pulse division rate by using pulse output
ratio (parameters No.276.0 and No.278,0) or decrease rotational speed to increase the pulse width.
Pulse width [ms] = 2 / rotational speed [
rpm
] / (division ratio × 2
17
) × 60 × 1,000.
Internal Position Command, Optional I/O Configuration
CN1 Connector Wiring Example
i/o
䐟
䐠
䐡
䐢
Содержание Control Techniques Digitax-SF DA21223
Страница 1: ...Instruction Manual AC SERVO MOTOR and SERVO DRIVE Series Digitax SF Part Number 0478 0606 01 Issue 1 ...
Страница 6: ...6 MEMO Digitax SF Instruction Manual ...
Страница 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Страница 138: ...5 5 Settings 1 Overview 2 3 3 4 4 5 6 7 17 19 20 21 22 23 24 27 28 30 34 39 52 64 68 76 82 84 88 96 98 ...
Страница 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Страница 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Страница 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Страница 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...
Страница 386: ...Digitax SF Instruction Manual 0478 0606 01 ...