51
5
Settings
5. Settings
Digitax SF
Instruction Manual
5. Parameters
5.
Parameters
No. 87.0
Position error detection:
Value
Range
Default
Characteristics
0 to 2,147,483,647
196,608
[encoder pulse]
Function
Use
This parameter sets a threshold value for a position error detection.
The higher the value, the less likely to detect position error.
(The initial value of 196,608 is equivalent to pulse count of rotor 1.5 rotations.)
Prerequisite
Position error detection: Switch (65.0)
= 1 (Enable)
Related To
No. 65.0, No. 89.0
No. 89.0
Position error detection:
Delay time
Range
Default
Characteristics
0 to 32,767
(See below)
Function
Use
This parameter sets a delay time for a position error (
Alarm
No.6) to be output
after the position
error
exceeded the setting of [Position error detection value
(87.0)]
The higher the value, the longer it takes for the error to be output.
Motor Capacity
Default
Converted to Time
50 W to 750 W
250 [160 µs]
40 [ms]
1 kW to 2 kW
200 [200 µs]
Prerequisite
Position error detection: Switch (65.0) = 1 (Enable)
Related To
No. 65.0, No. 87.0
No. 90.0
Speed error detection:
Value
Range
Default
Characteristics
0 to 32,767
(See below)
Function
Use
This parameter sets a threshold value for a speed error detecti
o
n.
The higher the value, the less likely to detect a speed error.
Motor Capacity
Default
Speed Conversion
50 W to 750 W
524 [encoder pulse/160 µs]
1,499 [
rpm
]
1 kW to 2 kW
655 [encoder pulse/200 µs]
Prerequisite
Speed error detection - Switch (65.1) = 1 (Enable)
Related To
No. 65.1, No. 91.0
No. 91.0
Speed error detection:
Delay time
Range
Default
Characteristics
0 to 32,767
(See below)
Function
Use
This parameter sets a delay time for a speed error (
Alarm
No.5) to be detected
after the speed
error
exceeded the setting of “Speed error - Detection
value”(90.0).
The higher the value, the longer the error detection time.
Motor Capacity
Default
Converted to Time
50 W to 750 W
250 [160 µs]
40 [ms]
1 kW to 2 kW
200 [200 µs]
Prerequisite
Speed error detection - Switch (65.1) = 1 (Enable)
Related To
No. 65.1, No. 90.0
-
-
-
-
Содержание Control Techniques Digitax-SF DA21223
Страница 1: ...Instruction Manual AC SERVO MOTOR and SERVO DRIVE Series Digitax SF Part Number 0478 0606 01 Issue 1 ...
Страница 6: ...6 MEMO Digitax SF Instruction Manual ...
Страница 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Страница 138: ...5 5 Settings 1 Overview 2 3 3 4 4 5 6 7 17 19 20 21 22 23 24 27 28 30 34 39 52 64 68 76 82 84 88 96 98 ...
Страница 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Страница 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Страница 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Страница 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...
Страница 386: ...Digitax SF Instruction Manual 0478 0606 01 ...