30
ON
ON
ON
OFF
OFF
2 ms(typ.)
ON
OFF
30
rpm
0
rpm
T1
(*2)
OFF
20 ms(typ.)
ON
25 ms(min.)
20 ms(typ.)
ON
150 ms(typ.)
150 ms(typ.)
(*1)
OFF
T1
(*2)
ON
t
ERROR
NO ERROR
OFF
( = ALARM )
ON
( = NO ALARM )
IN
OUT
Internal
IN
OUT
Internal
Internal
OUT
OUT
IN
3. Preparation
Digitax SF
Instruction Manual
3. Timing Diagrams
Alarm Reset (Servo ON)
*1)
Motor Excitation Status
remains OFF until motor rotational speed drops to 30 rpm or below.
*2) T1 is specified by B
r
ake release Delay time (No.238.0).
Signal Description
Name
Timing Diagrams
(Output Transistor Status, I/O Input Status, and Internal Status)
AC Supply
Power
L1L2
or
L1L2L3
Servo Ready
SRDY
Servo On
SVON
Reset
RESET
Internal Error Status
-
Motor Excitation Status
-
Deceleration Stop Status
-
Servo Status
SERVO
Motor
Brake Release
MBRK
Alarm Status
ALM
Motor Rotational Speed
-
3
Preparation
3.
Timing Diagrams
Содержание Control Techniques Digitax-SF DA21223
Страница 1: ...Instruction Manual AC SERVO MOTOR and SERVO DRIVE Series Digitax SF Part Number 0478 0606 01 Issue 1 ...
Страница 6: ...6 MEMO Digitax SF Instruction Manual ...
Страница 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Страница 138: ...5 5 Settings 1 Overview 2 3 3 4 4 5 6 7 17 19 20 21 22 23 24 27 28 30 34 39 52 64 68 76 82 84 88 96 98 ...
Страница 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Страница 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Страница 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Страница 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...
Страница 386: ...Digitax SF Instruction Manual 0478 0606 01 ...