22
8. Troubleshooting
Digitax SF
Instruction Man
ual
4. Troubleshooting
Problem 5(Positional
disturbance
)
Cause
Remedy
The command signal
has
electrical
noise
present
.
In Position Control/Pulse Train Command
Set
Pulse train command Input filter
(33.0) to an appropriate value.
Check the following three items.
1. Status No.33 (Pulse Train Command Input (position) agrees with the host
controller output.
2. Status No.65 “Position command” and Status No.67 “Position feedback”
agree.
3. (Status No.67) x (
Encoder pulse ratio
(276.0/278.0) = (Position feedback
from the host control device)
If the above
do not solve the problem
, take countermeasures for noise.
Connect
Ground/Earth
FG correctly.
Adjust
Pulse train command: Input filter
(33.0)
Select a shielded twist-pair wire for the I/O cable.
For the encoder cable, select a shielded twist
ed
-pair wire of no longer than
20m.
The position
error
is not
converging.
Verify that Status No.65 (Position command value) and Status No.67 (Position
feedback) agree.
If not, adjust the tuning parameters.
The host controller is not obtaining
encoder Z-phase correctly.
Check the command from the host controller.
Use
Digitax SF Connect
to measure the waveforms of Status No.33 “Pulse
Train Command Input (position)” or Status No.49 “Analog Velocity Command
Input” to verify that a normal command is input.
Verify that the host controller is obtaining Z-phase correctly. If the Z-phase
pulse width is too small, increase the pulse width by using the
Encoder pulse
ratio
(276.0/278.0) As a rule of thumb,
a
pulse width of 1 ms or above is
required for PLC.
Output pulse frequency of the host
controller is above the upper limit.
Verify that the output pulse frequency of the host controller such as PLC is
not above the upper limit.
A resistor is installed in the pulse
output circuit of the host controller
(PLC).
Verify that there is no built-in resistor in
the
pulse output terminal.
The output resistor of the host controller and the input resistor of servo
drive
being connected in series prevents correct command signal from
being input to the
drive
.
The motor does rotate, but position
disturbance
occurs.
Содержание Control Techniques Digitax-SF DA21223
Страница 1: ...Instruction Manual AC SERVO MOTOR and SERVO DRIVE Series Digitax SF Part Number 0478 0606 01 Issue 1 ...
Страница 6: ...6 MEMO Digitax SF Instruction Manual ...
Страница 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Страница 138: ...5 5 Settings 1 Overview 2 3 3 4 4 5 6 7 17 19 20 21 22 23 24 27 28 30 34 39 52 64 68 76 82 84 88 96 98 ...
Страница 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Страница 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Страница 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Страница 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...
Страница 386: ...Digitax SF Instruction Manual 0478 0606 01 ...