75
5
Settings
5. Settings
Digitax SF
Instruction Manual
5. Parameters
5.
Parameters
No. 236.0
Quick stop:
Extention Time
Range
Default
Characteristics
0 to 3,125
(See below)
Function
Use
This item indicates how long the quick stop to be kept
active
after the
deceleration stop complete conditions were met.
It is used to compensate the
motor
brake response time.
Motor Capacity
Default
Units
Converting to Time
50 W to 750 W
0
160 µs
0 [ms]
1 kW to 2 kW
0
200 µs
This parameter is valid only when the Deceleration Stop Method is “quick stop”.
This parameter is invalid if the servo turns off while the motor idling.
Use
Servo OFF: Delay time
(237.0) to compensate the
motor
brake response time when the
servo turns off during motor idling.
Prerequisite
Deceleration stop: Method (224.0) = 2 (Quick stop)
Related To
No. 224,0, No. 233.0, No. 237.0
No. 237.0
Servo OFF: Delay time
Range
Default
Characteristics
0 to 3,125
(See below)
Function
Use
This parameter indicates the delay time the motor excitation off after the servo-on
signal (SVON) turns off.
By adjusting the timing to end motor excitation after the
motor
brake is engaged, brake-
equipped axes such as vertical axis can be prevented from
roll back
.
Motor Capacity
Default
Units
Converting to Time
50 W to 750 W
0
160 µs
0 [ms]
1 kW to 2 kW
0
200 µs
Related To
No. 238.0
No. 238.0
B
r
ake release: Delay time
Range
Default
Characteristics
0 to 3,125
(See below)
Function
Use
This item indicates the delay time of
the motor
brake release signal (MBRK) ON after
the motor
excitation
starts.
By adjusting the timing to release the brake after the
motor excitation
starts, brake-equipped axes
such as vertical axis can be prevented from
roll back
.
Motor Capacity
Default
Units
Converting to Time
50 W to 750 W
25
160 µs
4 [ms]
1 kW to 2 kW
20
200 µs
Related To
No. 237.0
No. 239.0
Quick stop:
Deceleration time
Range
Default
Characteristics
0 to 100
0
[ms]
Function
Use
This item indicates decelerating time after a quick stop.
Set the time-length for speed command to change from 1,000 [
rpm
] to 0 [
rpm
].
Related To
No. 224.0, No. 232.2, No. 236.0
-
-
-
-
Содержание Control Techniques Digitax-SF DA21223
Страница 1: ...Instruction Manual AC SERVO MOTOR and SERVO DRIVE Series Digitax SF Part Number 0478 0606 01 Issue 1 ...
Страница 6: ...6 MEMO Digitax SF Instruction Manual ...
Страница 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Страница 138: ...5 5 Settings 1 Overview 2 3 3 4 4 5 6 7 17 19 20 21 22 23 24 27 28 30 34 39 52 64 68 76 82 84 88 96 98 ...
Страница 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Страница 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Страница 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Страница 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...
Страница 386: ...Digitax SF Instruction Manual 0478 0606 01 ...