![Nidec Control Techniques Digitax-SF DA21223 Скачать руководство пользователя страница 178](http://html1.mh-extra.com/html/nidec/control-techniques-digitax-sf-da21223/control-techniques-digitax-sf-da21223_instruction-manual_1687967178.webp)
41
5
Settings
5. Settings
Digitax SF
Instruction Manual
5. Parameters
5.
Parameters
No. 64.0
Positioning complete:
Determination method
Settings
Default
Characteristics
0, 1
0
Function
Use
Select one of two methods to output the Positioning Complete signal.
Settings
Signal Output Conditions
Position
Error
Speed
Pulse Train
command input Parameter settings
0
○
○
-
Detection criteria
- Range(68.0)
- Speed(69.0)
1
○
○
○
Detection criteria
- Range(68.0)
- Speed(69.0)
- command input(70.0)
Related To
No. 68.0, No. 69.0, No. 70.0, No. 71.0
No. 65.0
Position error detection:
Select s
witch
Settings
Default
Characteristics
0 to 3
1
Function
Use
Specify what to output when excessive position
error
is detected.
Settings
Output selection
0
No detect (No output)
1
Alarm output
2
Warning output
3
Alarm and Warning output
When using Torque command limit, select 0 (No output) so that an alarm will not occur in a torque
limit state.
Related To
No. 87.0, No. 89.0, No. 363.0, No. 365.0
No. 65.1
Speed error detection:
Enable s
witch
Settings
Default
Characteristics
0, 1
1
Function
Use
Enable/Disable Speed Error Detection.
Settings
Speed error detection
0
Disable
1
Enable
When using Torque command limit, select “Disable” so that an alarm will not occur during limiting.
Related To
No. 90.0, No. 91.0
-
-
Содержание Control Techniques Digitax-SF DA21223
Страница 1: ...Instruction Manual AC SERVO MOTOR and SERVO DRIVE Series Digitax SF Part Number 0478 0606 01 Issue 1 ...
Страница 6: ...6 MEMO Digitax SF Instruction Manual ...
Страница 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Страница 138: ...5 5 Settings 1 Overview 2 3 3 4 4 5 6 7 17 19 20 21 22 23 24 27 28 30 34 39 52 64 68 76 82 84 88 96 98 ...
Страница 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Страница 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Страница 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Страница 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...
Страница 386: ...Digitax SF Instruction Manual 0478 0606 01 ...