28
Digitax SF
Instruction Ma
nual
7. Tuning
3. Tuning Parameters
Function
Change the mode based on the direction of the load inertia and whether offset load is
present or not�
Parameter
110.0
Settings
Mode
Balanced load or unbalanced load
1
Standard Mode
Balanced load (horizontal motion)
2
(Default)
Unbalanced Load
Mode
Unbalanced load such as gravity is present
Remark
Use the Unbalanced Load Mode even for the case of balanced load (horizontal-axis
motion)�
Prerequisite
Position Control Mode, Velocity Control Mode
Function
Setting the item(s) to be estimated during tuning�
Parameter
110.1
Settings(Tuning)
Estimate items
Inertia ratio
Damping ratio
0
(Tuning Stop)
(Default)
Do not estimate
Do not estimate
1
(Tuning Start)
Estimate
2(Tuning Start)
Estimate
Prerequisite
Position Control Mode, Velocity Control Mode
Mode Switch
Tuning Items
Содержание Control Techniques Digitax-SF DA21223
Страница 1: ...Instruction Manual AC SERVO MOTOR and SERVO DRIVE Series Digitax SF Part Number 0478 0606 01 Issue 1 ...
Страница 6: ...6 MEMO Digitax SF Instruction Manual ...
Страница 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Страница 138: ...5 5 Settings 1 Overview 2 3 3 4 4 5 6 7 17 19 20 21 22 23 24 27 28 30 34 39 52 64 68 76 82 84 88 96 98 ...
Страница 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Страница 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Страница 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Страница 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...
Страница 386: ...Digitax SF Instruction Manual 0478 0606 01 ...