34
5. Settings
Digitax SF I
nstruction Man
ual
5. Parameters
2. Details of Parameters
No. 2.0
Control mode
Settings
Default
Characteristics
0 to 2
0
Function
Use
Select Control Mode
Settings
Control Mode
0
Position Control Mode
1
Velocity Control Mode
2
Torque Control Mode
Related To
No. 3.0, No. 642.0
No. 3.0
Command mode
Settings
Default
Characteristics
0 to 3
1
Function
Use
Select Command Mode
Control Mode
Settings
0: Position
1: Velocity
2: Torque
1
: Pulse train command input
Yes
-
-
2
: Analog command
-
Yes
Yes
3
: Internal command
Yes
Yes
-
Related To
No. 3.0, No. 642.0
No. 4.0
RS-485 communication:
Address
Settings
Default
Characteristics
1 to 32
1
Function
Use
Specify the address of the RS-485 communication.
Remark
Set this parameter to a unique address for each
drive
.
Related To
No. 6.0, No. 6.1, No. 6.2, No. 8.0, No. 11.0
No. 6.0
RS-485 communication:
Communication speed
Settings
Default
Characteristics
0 to 5
5
Function
Use
Specify the communications speed for the RS-485 communication.
Settings
Communications Speed [bps]
0
2,400
1
4,800
2
9,600
3
19,200
4
38,400
5
57,600
Related To
No. 4.0, No. 6.1, No. 6.2, No. 8.0, No. 11.0
Содержание Control Techniques Digitax-SF DA21223
Страница 1: ...Instruction Manual AC SERVO MOTOR and SERVO DRIVE Series Digitax SF Part Number 0478 0606 01 Issue 1 ...
Страница 6: ...6 MEMO Digitax SF Instruction Manual ...
Страница 23: ...17 MEMO Digitax SF Instruction Manual 1 Before Use 2 Overview ...
Страница 138: ...5 5 Settings 1 Overview 2 3 3 4 4 5 6 7 17 19 20 21 22 23 24 27 28 30 34 39 52 64 68 76 82 84 88 96 98 ...
Страница 283: ...48 MEMO Digitax SF Instruction Manual 6 Operation 5 Position Control Mode ...
Страница 329: ...46 MEMO Digitax SF Instruction Manual 7 Tuning ...
Страница 330: ...8 8 Troubleshooting 2 2 4 5 5 6 8 8 9 17 18 19 20 21 22 23 ...
Страница 353: ...24 MEMO 8 Troubleshooting Digitx SF Instruction Manual ...
Страница 386: ...Digitax SF Instruction Manual 0478 0606 01 ...