Chapter 4
Software Reference
© National Instruments Corp.
4-33
GPIB-410 User Manual
You can only terminate the
GPIB410
program when the Program Exit
screen is active. This screen contains one field.
•
Save Current Configuration Before Exiting?
Save Current Configuration Before Exiting?
Use this field to specify whether to save to disk the current state of the
GPIB-410 software before you exit. There are two options.
•
yes
(save configuration to disk)
•
no
(do not save configuration)
Selecting
yes
causes the field contents of the following screens to be
saved to the indicated file upon program exit.
•
Capture Settings Screen
•
Trigger Specification Screen
•
Pattern Generator Screen
•
Configuration Settings Screen
Press <Esc> while the Program Exit Screen is active to execute the
selected option and exit the program. Press any other screen function
key to abort the exit sequence and go to that screen.
Note:
The default configuration file pathname is
\GPIB410.CFG
.
The software automatically searches for this file on program
startup and, if found, loads its contents. If you use a different
configuration file pathname, you must explicitly name the file
on the DOS command line to reload when you later restart the
program, for example,
A>gpib410 myfile.cfg.