![NI GPIB-410 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/ni/gpib-410/gpib-410_user-manual_1685507033.webp)
Overview
Chapter 3
GPIB-410 User Manual
3-10
© National Instruments Corp.
<Alt-A> Acceptor Handshaker
Use this mode when you want the GPIB-410 to perform a dummy
acceptor handshake automatically whenever the DAV line is asserted.
The accepted data or command bytes are not saved unless capturing is
also enabled (use <Alt-C>). When this mode is active,
ACP
is
displayed in the Title/Status bar and
A
is displayed in the DOS shell
icon.
<Alt-S> Source Handshaker
Use this mode when you want the GPIB-410 to perform a dummy source
handshake automatically whenever the NRFD line is unasserted. The
handshake is performed regardless of the current state of the other GPIB
lines. When this mode is active,
SRC
is displayed in the Title/Status
bar and
S
is displayed in the DOS shell icon. This mode cannot be
enabled when the Pattern Generator is enabled.
<Alt-D> DOS Shell
Use this function to escape to DOS temporarily without terminating the
GPIB410
program. All enabled operational modes remain active while
the main program is suspended. To exit the shell and return control to
the
GPIB410
program, type
EXIT
at the DOS prompt.
<Alt-I> DOS Shell + Icon
Use this function to escape to DOS temporarily without terminating the
GPIB410
program. During operation of the shell, a GPIB-410 icon is
displayed in the upper right-hand corner of the screen showing the
operational modes in effect and the current state of the GPIB signal
lines. The layout of the icon signal lines is the same as that shown in
the monitor window. All enabled operational modes remain active
while the main program is suspended. To exit the shell and return
control to the
GPIB410
program, type
EXIT
at the DOS prompt. See