![background image](http://html1.mh-extra.com/html/nec/v850e-dx3/v850e-dx3_preliminary-users-manual_4115960471.webp)
471
16-bit Multi-Purpose Timer G (TMG)
Chapter 13
Preliminary User’s Manual U17566EE1V2UM00
(d) When a value exceeding the value set in GCCn0 or GCCn5 is set in
GCCnm (match and clear)
When a value exceeding the value set in GCCn0 (GCCn5) is set in GCCnm,
TOGnm starts and continues outputting the active level immediately after the
first match and clear event (until count operation stops.)
The figure shows the state of TOGn1 when 0FFFH is set in GCCn0, 1FFFH is
set in GCCn1, and TMGn0 is selected.
Figure 13-18
Timing when the value of GCCnm exceeding GCCn0 or GCCn5
(match and clear)
Low
ENFG0
TMGn0
GCCn1
INTTGnCC1
INTTGnCC0
0FFFH
0FFFH
0FFFH
1FFFH
TOGn1(ALVG1=0)
TOGn1(ALVG1=1)