690
Chapter 19
CAN Controller (CAN)
Preliminary User’s Manual U17566EE1V2UM00
(10)
CnIE - CANn module interrupt enable register
The CnIE register is used to enable or disable the interrupts of the CAN
module.
(a) Read
(b) Write
After reset: 0000H
R/W
Address: CnIE <CnRBaseAddr> + 056
H
15
14
13
12
11
10
9
8
CnIE
0
0
0
0
0
0
0
0
7
6
5
4
3
2
1
0
0
0
CIE5
CIE4
CIE3
CIE2
CIE1
CIE0
CIE5 to CIE0
CAN module interrupt enable bit
0
Output of the interrupt corresponding to interrupt status
register CINTSx is disabled.
1
Output of the interrupt corresponding to interrupt status
register CINTSx is enabled.
15
14
13
12
11
10
9
8
CnIE
0
0
Set
CIE5
Set
CIE4
Set
CIE3
Set
CIE2
Set
CIE1
Set
CIE0
7
6
5
4
3
2
1
0
0
0
Clear
CIE5
Clear
CIE4
Clear
CIE3
Clear
CIE2
Clear
CIE1
Clear
CIE0
Set CIE5
Clear CIE5
Setting of CIE5 bit
0
1
CIE5 bit is cleared to 0.
1
0
CIE5 bit is set to 1.
Other than above
CIE5 bit is not changed.
Set CIE4
Clear CIE4
Setting of CIE4 bit
0
1
CIE4 bit is cleared to 0.
1
0
CIE4 bit is set to 1.
Other than above
CIE4 bit is not changed.
Set CIE3
Clear CIE3
Setting of CIE3 bit
0
1
CIE3 bit is cleared to 0.
1
0
CIE3 bit is set to 1.
Other than above
CIE3 bit is not changed.