886
Chapter 28
On-Chip Debug Unit
Preliminary User’s Manual U17566EE1V2UM00
28.4 Connection to N-Wire Emulator
To connect the N-Wire emulator, a connector for emulator connection and a
connection circuit must be mounted on the target system.
As a connector example the KEL connector is described in more detail. Other
connectors, like for instance MICTOR connector (product name: 2-767004-2,
Tyco Electronics AMP K.K.), are available as well. For the mechanical and
electrical specification of these connectors refer to user’s manual of the
emulator to be used.
28.4.1
KEL connector
KEL connector product names:
• 8830E-026-170S (KEL): straight type
• 8830E-026-170L (KEL): right-angle type
Figure 28-4
Connection to N-Wire emulator (NEC Electronics IE-V850E1-CD-NW:
N-Wire Card)
electronic components distributor