186
-
'11 • SCM-SM-110
Necessary tools for the installation work
1
2
3
4
5
6
7
8
9
10
11
12
13
1
1
1
9
2
2
2
2
1
1
1
1
1
1
1
Q'ty
Q'ty
Standard accessories (Installation kit)
Accessories for indoor unit
Installation board
(Attached to the rear of the indoor unit)
Wireless remote control
Remote control holder
Battery [R03(AAA,Micro) 1.5V]
Air-cleaning filters
Filter holders
(Attached to the front panel of indoor unit)
Pipe cover (200mm)
2
Band
Tapping screws
(for installation board 4dia. by 25mm)
Wood screws
(for remote control switch holder 3.5(mm). by 16mm)
Option parts
Sealing plate
Sleeve
Inclination plate
Putty
Drain hose (extention hose)
Piping cover
(for insulation of connection piping)
Plus headed driver
Knife
Saw
Tape measure
Hammer
Spanner wrench
Torque wrench
Hole core drill (65mm in diameter)
Wrench key (Hexagon) [4m/m]
Flaring tool set
Gas leak detector
Pipe bender
Gauge for projection adjustment
Used when flare is made by using
conventional flare tool
(
)
(
)
)
(
14.0 ~ 61.0N m
(1.4 ~ 6.1kgf m)
(
Designed specifically
for R410A
Designed specifically
for R410A
)
2
3
4
5
6
7
8
9
10
18.5
Wireless remote control
Remote control holder
Wood screws
Piping is possible in the rear,
left,left rear, left downward,
right or downward direction.
Right
Rear
Downward
Left rear
Left downward
Left
15
60
60
60
85.3 22.7
100
55
157.2
76.3
45
65
65
65
470
80
91.5
65
45
For Right or Left rear piping
Right rear piping
Left rear piping
For Right or Left piping
Right/Left piping
For Right or Left bottom piping
Left bottom piping
Right bottom piping
Latch
The screw of the lid
is tightened securely.
Latch
BEFORE INSTALLATION
Before installation check that the power supply matches the air conditioner.
SELECTION OF INSTALLATION LOCATION
INSTALLATION OF INDOOR UNIT
Indoor unit
Installing the support of piping
(Install at location that meets the following conditions, after getting approval from the customer)
Where there is no obstructions to the air flow and where the cooled and heated air can be evenly distributed.
A solid place where the unit or the wall will not vibrate.
A place where there will be enough space for servicing. (Where space mentioned below can be secured)
Where wiring and the piping work will be easy to conduct.
The place where receiving part is not exposed to the direct rays of the sun or the strong rays of the street lighting.
A place where it can be easily drained.
A place separated at least 1m away from the television or the radio. (To prevent interference to images and sounds.)
Places where this unit is not affected by the high frequency equipment or electric equipment.
Avoid installing this unit in place where there is much oil mist.
Places where there is no electric equipment or household under the installing unit.
Install the indoor unit on flat wall.
Wireless remote control
In case of piping in the right rear direction
A place where the air conditioner can be received the signal surely during operating the wireless remote control.
Places where there is no affected by the TV and radio etc.
Do not place where exposed to direct sunlight or near heat devices such as a stove.
Drill a hole with whole core drill.
In case of rear piping draw out, cut off the lower
and the right side portions of the sleeve collar.
Tape only the portion
that goes through the
wall.
Always tape the wiring
with the piping.
Sufficient care must be taken not to damage
the panel when connecting pipes.
When drilling the wall that contains a metal lath, wire lath or metal plate, be sure to use pipe hole sleeve sold separately.
Drilling of holes and fixture of sleeve (Option parts)
Taping of the exterior
Top
Indoor side
Outdoor side
Thicknese of the wall + 1.5cm
5
65
Indoor side
Outdoor side
Installed state
Turn to
tighten
b
b
c
a
Open and detachment of the air inlet panel
To open, pull the panel at both ends of upper part
and release latches, and undo the strings.
Then remove the panel.
How to remove the front panel
Indoor unit piping direction
1
Remove the air inlet panel.
2
Remove the 5 set screws.
3
Remove the 3 latches in the upper section.
If the latches are difficult to remove, push the latch
portion out using a screw driver, for example.
4
Move the lower part of the panel forward and
remove the 6 latches in the under section.
CAUTION
Arrange the drain hose in a downward angle
Avoid the following drain piping.
Pour water to the drain pan located under the heat exchanger, and ensure that the water is discharged outdoor.
When the extended drain hose is indoor, securely insulate it with a heat insulator available in the market.
Drainage
Go through all installation steps and check if the
dralnage is all right. Otherwise water leak may occur.
Higher than specified The drain hose
tip is in water
Wavy
The gap to the ground is
5 cm or less
The drain hose
tip is in the gutter
Odor from
the gutter
CAUTION
Completely seal the hole on
the wall with putty. Otherwise,
furniture, or other, may be
wetted by leaked water or
dewing.
putty
putty
Indoor side
Outdoor side
Installation board
5 cm minimum
from the wall
from the wall
5 cm +
Service space (30c
m)
7 cm minimum from the ceiling
15 cm or below from the floor
Sleeve
(sold separately)
When removing the air-inlet panel,
be careful not to drop it on your feet.
CAUTION
1
Be careful not to
stress the connecting
refrigerant pipse. (Do
not pull with a force of
larger than 5 kgf.) If
improperly installed,
it may cause abnormal
noise and vibration.
CAUTION
Содержание SCM100ZJ-S1
Страница 64: ...63 11 SCM SM 110 Service data record form 55...
Страница 194: ...193 11 SCM SM 110 4 Ceiling cassette 4way compact type FDTC refer to page 157 to 172...
Страница 198: ...197 11 SCM SM 110 PJAO12D786...
Страница 223: ...222 11 SCM SM 110 4 way valve coil 1 Disconnect the connector 2 Loosen a screw and remove the coil Connector Screw Coil...
Страница 237: ...236 11 SCM SM 110 EEVB EEVC EEVA EEVD MARKING GREEN BLUE RED WHITE EEV A EEV D 46 WH 46 46 46 M YE OR BL RD Input 12VDC...