(8) Flap and louver control (SRK and SRF series only)
S
SRK series
Control the flap and louver by AIRFLOW
(UP/DOWN) and
(LEFT/RIGHT) button on the wireless remote controller.
(a) Flap
Each time when you press the AIRFLOW
(UP/DOWN) button the mode changes as follows.
COOL , DRY, FAN
Remote controller
display
HEAT
Approx. 5°
Approx. 20°
Approx. 20°
Approx. 35°
Approx. 35°
Approx. 45°
Approx. 75°
(Swing)
(Flap stopped)
Approx. 45°
Approx. 60°
Approx. 60°
Angle of Flap from Horizontal
Model SRK20, 25, 35ZJX-S, 50, 60ZJX-S1
COOL , DRY, FAN
Remote controller
display
HEAT
Approx. 10°
Approx. 25°
Approx. 25°
Approx. 40°
Approx. 40°
Approx. 50°
Approx. 70°
Approx. 50°
Approx. 60°
Approx. 60°
Model SRK25, 35ZJR-S, 20, 25, 35, 50ZJ-S
COOL , DRY, FAN
Remote controller
display
HEAT
Approx. 5°
Approx. 25°
Approx. 25°
Approx. 40°
Approx. 35°
Approx. 50°
Approx. 80°
Approx. 55°
Approx. 60°
Approx. 80°
Model SRK71ZK-S
(7) Econo operation
Pressing the HI POWER/ECONO button initiate a soft operation with the power suppressed in order to avoid an excessive cooling
or heating. The unit operate 1.5
℃
higher than the setting temperature during cooling or 2.5
℃
lower than that during heating. The
remote control displays ECONO mark and the FAN SPEED display disappears.
(a) It will go into ECONOMY operation at the next time the air conditioner runs in the following cases.
①
When the air-conditioner is stopped by ON/OFF button during ECONOMY operation.
②
When the air-conditioner is stopped in SLEEP or OFF TIMER operation during ECONOMY operation.
③
When the operation is retrieved from CLEAN or ALLERGEN CLEAR operation.
(b) When the following operation are set, ECONOMY operation will be canceled.
①
When the HI POWER/ECONO button is pressed again.
②
When the operation mode is changed DRY to FAN.
(c) Not operable while the air-conditioner is OFF.
(d) The setting temperature is adjusted according to the following table.
①
at the start of operation.
②
one hour after the start of operation.
③
two hours after the start of operation.
Temperature
adjustment
Cooling
Heating
①+0.5
①-1.0
②+1.0
②-2.0
③+1.5
③-2.5
Mode
Item
Содержание SCM100ZJ-S1
Страница 64: ...63 11 SCM SM 110 Service data record form 55...
Страница 194: ...193 11 SCM SM 110 4 Ceiling cassette 4way compact type FDTC refer to page 157 to 172...
Страница 198: ...197 11 SCM SM 110 PJAO12D786...
Страница 223: ...222 11 SCM SM 110 4 way valve coil 1 Disconnect the connector 2 Loosen a screw and remove the coil Connector Screw Coil...
Страница 237: ...236 11 SCM SM 110 EEVB EEVC EEVA EEVD MARKING GREEN BLUE RED WHITE EEV A EEV D 46 WH 46 46 46 M YE OR BL RD Input 12VDC...