'11 • SCM-SM-110
Model SCM100ZJ-S1
R
WC000Z247
L
N
RD
RD
WH
30A 250V
Y/G
TB3
TB4
TB5
TB6
TB7
TB8
RD
WH
TB3
TB4
TB5
TB6
TB7
RD
WH
2
㨪
AC
3
㨪
+1
-4
RD
BL
P1
N1
1
2
4
3
P2
N2
RD
BL
+
-
L1
L2
CNACT
P
N2
㧔
BK
㧕
RD
RD
BL
BL
CNACT1
P3
N3
BL
RD
RD
U
WH
V
BL
W
U
V
W
MS
3
㨪
CNI2
CNI4
CNI1
CNI3
CNA2
CNA1
BL
4
BL
3
4A
250V
Y/G
Y/G
Y/G
RD
WH
RD
WH
L-IN N-IN
CNTRI
CNTRO
CNS2
CNX2
G
WH
RD
BK
WH
BK
WH
Y/G
CNA
CNB
CNC
CND
CNE
CN
EEV1
CN
EEV2
CN
EEV3
4
+
5
5
5
5
5
BK
1
2
3
WH
RD
BK
WH
BR
BK
WH
BL
BK
WH
Y
BK
WH
OR
t°
CNW
CNS1
CNX1
CNTH
CNP1
2
2
2
2
2
UNIT A
UNIT B
UNIT C
UNIT D
UNIT E
2
2
5
5
5
5
5
BL
RD
WH
GN
BK
㧔
WH
㧕
㧔
WH
㧕
㧔
WH
㧕
㧔
WH
㧕
㧔
WH
㧕
㧔
WH
㧕
㧔
WH
㧕 㧔
WH
㧕
㧔
Y
㧕
㧔
BK
㧕
㧔
WH
㧕
㧔
WH
㧕
㧔
BK
㧕
㧔
Y
㧕
㧔
BK
㧕
㧔
WH
㧕
㧔
GN
㧕
㧔
WH
㧕
㧔
WH
㧕
CN
EEV1
5
M
㧔
RD
㧕
M
5
CNL1
㧔
BL
㧕
CN
FAN1
㧔
WH
㧕
3
CNR1
㧔
WH
㧕
2
CNN1
㧔
RD
㧕
2
POWER SOURCE
㨪
220/230/240V
50Hz
3
BK
BK
BK
Y
BK
BR
BL
M
M
M
M
M
LED1
LED2
LED3
CHECKER
PC
CNE
※
CNV
̪
㧔
WH
㧕
1
2
3
1
2
3
1
2
3
1
2
3
1.Instructions for correct operation
٧
Before you turn on power,please carefully read the installation
ޓ
manual and the operation manual supplied with the unit.
٧
Please check the following points before operation.
Ԙ
This unit is designed exclusively for use with R410A. Do not use
ޓޓ
ޓ
any refrigerant other than R410A.
ԙ
To protect the compressor,turn on power for the air conditioner
ޓ
6 hours before operation so as warm up sufficiently the dome
ޓ
temperature of compressor.
Ԛ
Open the service valves of liquid pipe at first. Secondarily open
ޓ
the one of gas pipe. Before you operate the unit,make sure again
ޓ
that the service valves are in open position.
ԛ
Please note that the pressure valves detected at the charge port
ޓ
in the unit and the gas service valves are different during the
ޓ
cooling operation and the heating operation. High pressure is
ޓ
replaced with the low pressure depending on whether it is in the
ޓ
cooling or heating operation.
2.Error indication
t°
t°
t°
t°
TB
1
PWB5
NOISE
PWB3
CT1
DS
L
A
㧛
F
PWB2
INV PWB
IPM
30A 600V
CM
F
PWB1
CONTROL PWB
PWB4
SUB PWB
C1
EEV
A
EEV
B
EEV
C
EEV
D
EEV
E
TB
2
TB
3
Tho-R
Tho-D
Tho-S
Tho-A
Tho-AF
TR
F
2
FILTER
NOISE
FILTER
1
EEV-H
HPS
CH
20S
FM
MODULE
CH
Crankcase heater
HPS
CM
DS
EEV
Compressor motor
Diode stack
Electronic expansion coil
EEV-H
Electronic expansion coil
㧔
For heating
㧕
FM
Fan motor
CT
Current sensor
High pressure sensor
F
Fuse
Tho-A
Thermistor
㧔
outdoor air temperature
㧕
Mark
Name
CNA
㨪
Z
Tho-D
Thermistor
㧔
discharge pipe
㧕
Tho-R
Thermistor
㧔
heat exchanger
㧕
Tho-S
Thermistor
㧔
suction pipe
㧕
Tho-AF
Thermistor
㧔
power transistor
㧕
20S
4-way valve coil
IPM
Intelligent power module
LED1
Indicator lamp
㧔
Red-Inspection indicator
㧕
LED2
Indicator lamp
㧔
Green-Microcomputer normality indicator
㧕
LED3
Indicator lamp
㧔
Green-For service
㧕
TR
Trance former
TB
Terminal block
L
Reactor
Connector
A/F MODULE Active filter module
LED E
㧔
1
㧕
RED
WARNING LAMP
INDICATION LAMP
COLOR
FUNCTION
SELF DIAGNOSIS FUNCTION BY LED E
1 TIME FLASH
2 TIME FLASH
CURRENT CUT
TROUBLE OF OUTDOOR UNIT
FOUR SEC LIGHT
3 TIME FLASH
5 TIME FLASH
6 TIME FLASH
OVER CURRENT
OVER HEAT OF COMPRESSOR
ERROR OF SIGNAL TRANSMISSION
DISCHARGE PIPE SENSOR ERROR
AND
FOUR SEC OFF
8 TIME FLASH
SENSOR ERROR
㧔
EXCEPT DISCHARGE PIPE SENSOR
㧕
LIGHT ON
OUTDOOR FAN MOTOR ERROR
4 TIME FLASH
TRANSMISSION ERROR
Color
RD
Mark
Yellow
㧛
Green
Y
㧛
G
Black
BK
Blue
BL
Brown
BR
Yellow
Y
White
WH
Red
Orange
OR
Pink
PK
Green
GN
※
used only at our factory
-
140
-
#
Содержание SCM100ZJ-S1
Страница 64: ...63 11 SCM SM 110 Service data record form 55...
Страница 194: ...193 11 SCM SM 110 4 Ceiling cassette 4way compact type FDTC refer to page 157 to 172...
Страница 198: ...197 11 SCM SM 110 PJAO12D786...
Страница 223: ...222 11 SCM SM 110 4 way valve coil 1 Disconnect the connector 2 Loosen a screw and remove the coil Connector Screw Coil...
Страница 237: ...236 11 SCM SM 110 EEVB EEVC EEVA EEVD MARKING GREEN BLUE RED WHITE EEV A EEV D 46 WH 46 46 46 M YE OR BL RD Input 12VDC...