104
-
'11 • SCM-SM-110
Error code
Remote controller:
LED
Green
Red
Indoor
Stays OFF
Keeps flashing
Content
WAIT
Communication error at
initial operation (3/3)
Outdoor
–
Stays OFF
1. Applicable model
5. Troubleshooting
All models
When the remote controller
display is extinguished after the
power on.
Diagnosis
Countermeasure
YES
NO
Remote controller display is
extinguished after the power on.
NO
NO
Is the
green LED on the indoor unit
flashing?
Is the
fuse on the indoor control
PCB OK?
Is AC
19V or higher detected
between Red-Red at the secondary side of
indoor unit transformer?
YES
Is
approx. 10-11V detected
between wires at the remote controller
side after disconnecting the
remote controller?
Are wires
connected properly between the indoor and
the outdoor units?
Is approx.
DC20V detected between
�
-
�
on the outdoor unit terminal
block?
NO
Is approx
DC20V detected between
�
-
�
on the indoor unit terminal
block?
YES
NO
(1)
Note (1) FDEN only.
YES
YES
YES
YES
NO
NO
Replace fuse.
Defective transformer
Short-circuit on remote
controller wire
Defective remote controller
Correct wires.
Defective outdoor sub
PCB
➞
Replace.
Defective connection wire
(Broken wire)
Noise
Defective indoor control
PCB
➞
Replace.
2. Error detection method
3. Condition of Error displayed
4. Presumable cause
• Blown fuse
• Connection between PCB’s
• Blown fuse
• Faulty indoor control PCB
• Defective remote controller
• Wire breakage on remote
controller
• Faulty outdoor sub PCB
Note:
Содержание SCM100ZJ-S1
Страница 64: ...63 11 SCM SM 110 Service data record form 55...
Страница 194: ...193 11 SCM SM 110 4 Ceiling cassette 4way compact type FDTC refer to page 157 to 172...
Страница 198: ...197 11 SCM SM 110 PJAO12D786...
Страница 223: ...222 11 SCM SM 110 4 way valve coil 1 Disconnect the connector 2 Loosen a screw and remove the coil Connector Screw Coil...
Страница 237: ...236 11 SCM SM 110 EEVB EEVC EEVA EEVD MARKING GREEN BLUE RED WHITE EEV A EEV D 46 WH 46 46 46 M YE OR BL RD Input 12VDC...