'11 • SCM-SM-110
0 rps
A rps or less
More than A rps, but B rps or less
More than B rps
Decision speed
0 rps
A rps
A rps to B rps
B rps
Indoor compressor command total speed value
Model
A
B
30 rps
100 rps
SCM40ZJ-S
30 rps
120 rps
SCM45ZJ-S
30 rps
120 rps
SCM50ZJ-S1
20 rps
120 rps
SCM60ZJ-S1
20 rps
120 rps
SCM80ZJ-S1
20 rps
120 rps
SCM71ZJ-S1
Values of A, B
Model
A
B
20
̅
40 rps
110 rps
SCM100ZJ-S1
20
̅
45 rps
110 rps
SCM125ZJ-S1
1.4 Outline of cooling operation
(1) Summary
(a) Capacity control
1) Indoor unit SRK
**
ZJX models only
Model
Capacity
SCM40ZJ-S
1.8
̅
5.9 kW
SCM45ZJ-S
1.8
̅
6.4 kW
SCM50ZJ-S1
1.8
̅
7.1 kW
SCM60ZJ-S1
1.8
̅
7.5 kW
SCM80ZJ-S1
1.8
̅
9.2 kW
SCM71ZJ-S1
1.8
̅
8.8 kW
Model
Capacity
SCM100ZJ-S1
1.8
̅
12.0 kW
SCM125ZJ-S1
1.8
̅
14.0 kW
Capacity control is within the range shown above. If demand capacity of the indoor units exceeds the maximum capacity of
the outdoor unit, the demand capacity will be proportionally distributed.
(b) Outdoor compressor speed control
Model
Capacity
SCM40ZJ-S
1.8
̅
5.8 kW
SCM45ZJ-S
1.8
̅
6.3 kW
SCM50ZJ-S1
1.8
̅
6.9 kW
SCM60ZJ-S1
1.8
̅
7.3 kW
SCM80ZJ-S1
1.8
̅
8.7 kW
SCM71ZJ-S1
1.8
̅
8.3 kW
Model
Capacity
SCM100ZJ-S1
1.8
̅
11.8 kW
SCM125ZJ-S1
1.8
̅
13.8 kW
2) Indoor unit except SRK
**
ZJX models
Functional
components
Operation
Command speed
Indoor
unit fan
Compressor
Outdoor unit fan
Electronic
expansion valve
ON
According to command speed
According to outdoor unit speed
According to decision
speed
0
(All indoor units)
OFF
According to stop mode
According to mode switching
OFF
0
(Thermostat off units)
ON
All closed
(Thermostat off units)
According to outdoor unit speed
According to mode switching
All closed
(Fan, stop, abnormal stop units)
0
(Fan, stop, abnormal stop units)
0
(All units)
ON
According to command speed
OFF
OFF
According to stop mode
Cooling
Thermostat OFF
(All indoor units)
Thermostat OFF
(Some of indoor units)
Fan, stop, abnormal stop
(Some of indoor units)
Failure
(Outdoor unit)
Fixed
Automatic
Multi-operation rpm calculated based
on the rpm required for each indoor unit
(2) Operation of major functional components in cooling mode
Содержание SCM100ZJ-S1
Страница 64: ...63 11 SCM SM 110 Service data record form 55...
Страница 194: ...193 11 SCM SM 110 4 Ceiling cassette 4way compact type FDTC refer to page 157 to 172...
Страница 198: ...197 11 SCM SM 110 PJAO12D786...
Страница 223: ...222 11 SCM SM 110 4 way valve coil 1 Disconnect the connector 2 Loosen a screw and remove the coil Connector Screw Coil...
Страница 237: ...236 11 SCM SM 110 EEVB EEVC EEVA EEVD MARKING GREEN BLUE RED WHITE EEV A EEV D 46 WH 46 46 46 M YE OR BL RD Input 12VDC...