123
-
'11 • SCM-SM-110
Error code
Remote controller:
LED
Green
Red
Outdoor
Content
1 time flash
Indoor Keeps flashing
–
Stays OFF
E41
1. Applicable model
5. Troubleshooting
Model SCM100, 125 only
Diagnosis
Countermeasure
YES
YES
YES
YES
Correct.
Replace the fan motor or outdoor control
PCB.
Replace the power transistor
temperature thermistor.
* Characteristics of power transistor temperature thermistor
Is the
installation space of outdoor
unit enough?
Is the outdoor fan running?
NO
Are the
characteristics of power transistor temperature
thermistor OK?
Connect.
Is the power
transistor temperature thermistor connector
connection OK?
Is it OK the fixing
to power transistor radiator fin?
Does it recur?
NO
0
20
40
60
80
100
120
140
160
180
200
0
20
40
60
80
100
120
140
Temperature (°C)
Te
mperature thermistor resistance (k
Ω
)
NO
Temperature-resistance characteristics
NO
NO
NO
・
Fixed screw
・
Application of radiation
silicone
YES
Fix properly.
OK
2. Error detection method
Anomalous rise of the internal
power transistor temperature
3. Condition of Error displayed
When anomalous rise of the
power transistor temperature is
detected 2 times within 1 hour.
4. Presumable cause
• Defective inverter PCB
• Defective outdoor fan motor
• Delective power transistor
temperature thermistor
• Inadequate installation space
Note:
Power transistor overheat
(Model SCM100, 125)
Содержание SCM100ZJ-S1
Страница 64: ...63 11 SCM SM 110 Service data record form 55...
Страница 194: ...193 11 SCM SM 110 4 Ceiling cassette 4way compact type FDTC refer to page 157 to 172...
Страница 198: ...197 11 SCM SM 110 PJAO12D786...
Страница 223: ...222 11 SCM SM 110 4 way valve coil 1 Disconnect the connector 2 Loosen a screw and remove the coil Connector Screw Coil...
Страница 237: ...236 11 SCM SM 110 EEVB EEVC EEVA EEVD MARKING GREEN BLUE RED WHITE EEV A EEV D 46 WH 46 46 46 M YE OR BL RD Input 12VDC...