-
-
'11 • SCM-SM-110
1.5 Outline of automatic operation
(1) Determination of operation mode
(a) SRK20, 25, 35, 50, 60ZJX, SRF and SRR series
The unit checks the indoor air temperature and the outdoor air temperature after operating the indoor and outdoor blowers
for 0 seconds, determines the operation mode and the indoor air temperature setting correction value, and then enters in
the automatic operation.
27.5
25.5
19.5
18
30
Outdoor air temperature (°C)
Indoor air temperature (°C)
Dehumidifying
Heating
Cooling
) When the unit is operated automatically with the wired remote controller connected, the cooling operation is controlled accord-
ing to the display temperatures while the setting temperature is compensated by
+
°C during dehumidifying or by
+
°C during
heating.
◆
SRF series
◆
SRK, SRR series
Signals of wireless remote control (Display)
–6
–5
–4
–3
–2
–1
±
0
+1
+2
+3
+4
+5
+6
Setting
Cooling
0
0
temperature
Dehumidifying
0
0
Heating
0
0
Signals of wireless remote control (Display)
–6
–5
–4
–3
–2
–1
±
0
+1
+2
+3
+4
+5
+6
Setting
Cooling
0
0
temperature
Dehumidifying
0
0
Heating
0
0
Unit : °C
Unit : °C
27.5
25.5
18.0
18
30
(b)
SRK25, 35ZJR-S, 20, 25, 35, 50ZJ-S, 71ZK-S series
Heating
Dehumidifying
Cooling
Indoor air temperature (˚C)
Outdoor air temperature (˚C)
A
) The unit checks the temperature every hour after the start of operation and, if the result of check is not same as the previous
operation mode, changes the operation mode.
) When the unit is started again within one hour after the stop of automatic operation or when the automatic operation is se-
lected during heating, cooling or dehumidifying operation, the unit is operated in the previous operation mode.
) Setting temperature can be adjusted within the following range. There is the relationship as shown below between the sig-
nals of the wireless remote controller and the setting temperature.
Содержание SCM100ZJ-S1
Страница 64: ...63 11 SCM SM 110 Service data record form 55...
Страница 194: ...193 11 SCM SM 110 4 Ceiling cassette 4way compact type FDTC refer to page 157 to 172...
Страница 198: ...197 11 SCM SM 110 PJAO12D786...
Страница 223: ...222 11 SCM SM 110 4 way valve coil 1 Disconnect the connector 2 Loosen a screw and remove the coil Connector Screw Coil...
Страница 237: ...236 11 SCM SM 110 EEVB EEVC EEVA EEVD MARKING GREEN BLUE RED WHITE EEV A EEV D 46 WH 46 46 46 M YE OR BL RD Input 12VDC...