INSTALLATION INSTRUCTIONS

AND USER MANUAL

RESIDENTIAL USE ONLY

INSTALLER: LEAVE THIS MANUAL WITH THE HOMEOWNER.

HOMEOWNER: USE AND CARE INFORMATION ON PAGES 18 TO 20.

READ AND SAVE THESE INSTRUCTIONS

04313    rev. F

M O D E L S

VB0064

HEPA 3000*

HF 3.0*

HEPA 4000*

HRV 2500*

HR 2.5*

*Patents pending

NOTES: 1. HRV 2500* and HR 2.5* models are available in Canada only.

2. HEPA 4000* model is available in United States only.

Содержание HEPA 3000

Страница 1: ...OMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 18 TO 20 READ AND SAVE THESE INSTRUCTIONS 04313 rev F M O D E L S VB0064 HEPA 3000 HF 3 0 HEPA 4000 HRV 2500 HR 2 5 Patents pending NOTES 1 HRV 250...

Страница 2: ...et 4 Installation must be done in accordance with all applicable codes and standards including fire rated construction codes and standards 5 This unit is not designed to provide combustion and or dilu...

Страница 3: ...HANG THE UNIT 11 5 3 PLANNING OF THE DUCTWORK 12 5 4 INSTALLING NON INSULATED DUCTS AND REGISTERS 12 5 4 1 STAND ALONE SYSTEM 12 13 5 4 2 CENTRAL DRAW POINT 13 14 5 4 3 RETURN TO RETURN 14 5 5 INSTALL...

Страница 4: ...Fresh filtered air is supplied by the register located in the lowest liveable level See figure at right 1 1 2 CENTRAL DRAW POINT CONNECTION TO A FORCED AIR SYSTEM VH0040 ALL UNITS For this type of ins...

Страница 5: ...RRISBURG SACRAMENTO DENVER TOPEKA DETROI T INDIANAPOLIS SANTA FE SPRINGFIELD OKLAHOMA CITY PHOENI X COLUMBUS NASHVILLE ATLANTA BATON ROUGE AUSTIN COLUMBI A RALEIG H WASHINGTON HARTFORD BOSTON REN O HE...

Страница 6: ...of the forced air unit To avoid cross contamination and achieve the highest efficiencies the forced air system blower must always be ON See figure below NOTE Home with multiple forced air systems shou...

Страница 7: ...g the minimum clearance needed to open the door completely 22 5 15 75 572 mm 400 mm VD0117 VD0116 22 559 mm NOTE A minimum of 8 203 mm clearance from any obstruction on top of the unit is required for...

Страница 8: ...ction installation only to cut ductwork Aluminum duct tape for plenum connection installation only Jig saw Caulking gun and caulking For HRV 2500 and HR 2 5 units the installation kit is 15273 For HEP...

Страница 9: ...s the other end of the cable through the wall Reinstall the cover plate Using wall anchors and provided screws mount the wall control on the wall See illustrations below 1 Wall anchors 4 Control 1 Out...

Страница 10: ...d front plate of the unit at this time they need to be removed for preparing the unit to be hung 2 When using the wall control the main switch on the unit must always be positioned to NORMAL REMOTE 6...

Страница 11: ...ORTS ON THE UNIT Mount the 8 oval ports and the 5 to 6 oval ports on the top of the unit using the screws provided in the hardware box 4 screws 8 x 3 4 long per port See figure beside NOTE All ports o...

Страница 12: ...e air circulation Keep in mind that the filtered air register must be located as far as possible from the stale air register If desired you can install another register sold separately Install the reg...

Страница 13: ...ystem described in point 5 4 1 Fresh Filtered air ductwork Return side connection HRV 2500 AND HR 2 5 UNITS ONLY Locate the opening for fresh filtered air ductwork on the forced air unit at a minimum...

Страница 14: ...1 1 3 AND 1 2 2 Fresh Filtered air ductwork Return side connection Same as for Central Draw Point described in point 5 4 2 Stale air ductwork Return side connection ALL UNITS Locate the stale air duc...

Страница 15: ...the vapor barrier over the insulation 4 Apply duct tape gently to the joint in order to make an airtight seal See figures below Identify each insulated duct For fresh air from outside duct use the blu...

Страница 16: ...exterior hood must be installed at a minimum distance of 18 inches 457 mm from the ground See illustration beside 5 6 3 CONNECTING TANDEM TRANSITION TO THE DUAL EXTERIOR HOOD 1 Using a jig saw cut a 6...

Страница 17: ...the 2 plastic drain fittings 1 using the gaskets 2 and nuts 3 as shown Close the door VO0027 27 686 mm 7 178 mm 3 Cut 2 sections of plastic tubing one 7 178 mm long and one 27 686 mm long and attach...

Страница 18: ...from a wood stove through out the house or the fresh air from a cooling system 6 CONTROLS OFF UNIT IS OFF AND DOOR IS UNLOCKED NORMAL REMOTE UNIT IS OPERATING ON NORMAL SPEED THIS IS THE RIGHT POSITI...

Страница 19: ...cuum to remove most of the dust Let it soak in a solution of warm water and mild soap Rinse thoroughly and let dry before reinstalling it 5 Clean the inside walls of the unit with a clean damp cloth t...

Страница 20: ...control for HV 2 5 and HF 3 0 units only All listed parts are available where you have bought your unit NOTE Please note that parts not listed are not available those parts require assembly knowledge...