5 - 14
5. PARAMETERS
5.1.13 Selection of servo motor rotation direction
Parameter Control
Mode
No. Symbol
Name
Initial
Value
Unit
Setting
Range Position Speed Torque
PA14 *POL Rotation direction selection
0
0 1
POINT
This parameter is made valid when power is switched off, then on after setting.
Select servo motor rotation direction relative to the input pulse train.
Servo Motor Rotation Direction
Parameter No. PA14
Setting
When forward rotation pulse is
input (Note)
When reverse rotation pulse is
input (Note)
0 CCW CW
1 CW CCW
Forward rotation (CCW)
Reverse rotation (CW)
5.1.14 Encoder output pulse
Parameter Control
Mode
No. Symbol
Name
Initial
Value
Unit
Setting
Range Position Speed Torque
PA15 *ENR Encoder output pulse
4000
pulse/
rev
1 to
100000
POINT
This parameter is made valid when power is switched off, then on after setting.
Used to set the encoder pulses (A-phase, B-phase) output by the servo amplifier.
Set the value 4 times greater than the A-phase or B-phase pulses.
You can use parameter No. PC19 to choose the output pulse setting or output division ratio setting.
The number of A/B-phase pulses actually output is 1/4 times greater than the preset number of pulses.
The maximum output frequency is 4.6Mpps (after multiplication by 4). Use this parameter within this range.