5 - 42
5. PARAMETERS
5.4.2 List of details
Control Mode
No. Symbol
Name
and
Function
Initial
Value
Unit
Setting
Range Position Speed Torque
PD01 *DIA1 Input signal automatic ON selection 1
Select the input devices to be automatically turned ON.
0
0
0
BIN 0: Used as external input signal
BIN 1: Automatic ON
Initial value
BIN
HEX
Signal name
0
0
0
Initial value
BIN
HEX
Proportion control (PC)
Signal name
Initial value
BIN
HEX
Signal name
Servo-on (SON)
External torque limit (TL)
0
0
0
0
Forward rotation
stroke end (LSP)
0
0
0
0
0
0
Reverse rotation
stroke end (LSN)
For example, to turn ON SON, the setting is " 4".
0000h
Refer
to
the
Name
and
Function
field.
PD02
For manufacturer setting
Do not change this value by any means.
0000h
Refer
to
the
Name
and
Function
field.