1 - 21
1. FUNCTIONS AND CONFIGURATION
1.8 Configuration including auxiliary equipment
POINT
Equipment other than the servo amplifier and servo motor are optional or
recommended products.
(1) MR-J3-100A or less
(a) For 3-phase or 1-phase 200V to 230VAC
Line noise filter
(FR-BLF)
(Note3)
power supply
R S T
Magnetic
contactor
(MC)
No-fuse breaker
(NFB) or fuse
CN5
CN3
Regenerative
option
P
C
L
11
L
21
Power factor
improving DC
reactor
(FR-BEL)
Analog monitor
CN1
CN2
CN4
Junction terminal block
CN6
P
1
P
2
U V W
Servo amplifier
Servo motor
(Note1)
Battery unit
MR-J3BAT
L
1
L
2
L
3
(Note2)
(Note2)
MR Configurator
Personal
computer
Note 1. The battery unit(option) is used for the absolute position detection system in the position control mode.
2. The AC reactor can also be used. In this case, the DC reactor cannot be used.
3. A 1-phase 200V to 230VAC power supply may be used with the servo amplifier of MR-J3-70A or less.
For 1-phase 200V to 230VAC, connect the power supply to L
1
L
2
and leave L
3
open. For the specification of power supply,
refer to section 1.3.
Содержание MELSERVO MR-J3 A Series
Страница 15: ...A 14 MEMO ...
Страница 225: ...7 12 7 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 241: ...8 16 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 251: ...9 10 9 TROUBLESHOOTING MEMO ...
Страница 263: ...10 12 10 OUTLINE DRAWINGS MEMO ...