13 - 11
13. COMMUNICATION FUNCTION
(2) Parameters (Command [0][4] [0][5] [0][6] [0][7] [0][8] [0][9])
Command
Data No.
Description
Frame Length
[0] [4]
[0] [1]
Parameter group read
0000: Basic setting parameter (No.PA
)
0001: Gain filter parameter (No.PB
)
0002: Extension setting parameter (No.PC
)
0003: I/O setting parameter (No.PD
)
4
[0] [5]
[0] [1] to [F] [F] Current values of parameters
Reads the current values of the parameters in the parameter group specified with the
command [8][5] + data No. [0][0]. Before reading the current values, therefore, always
specify the parameter group with the command [8][5] + data No. [0][0].
The decimal equivalent of the data No. value (hexadecimal) corresponds to the
parameter number.
8
[0] [6]
[0] [1] to [F] [F] Upper limit values of parameter setting ranges
Reads the permissible upper limit values of the parameters in the parameter group
specified with the command [8][5] + data No. [0][0]. Before reading the upper limit
values, therefore, always specify the parameter group with the command [8][5] + data
No. [0][0].
The decimal equivalent of the data No. value (hexadecimal) corresponds to the
parameter number.
8
[0] [7]
[0] [1] to [F] [F] Lower limit values of parameter setting ranges
Reads the permissible lower limit values of the parameters in the parameter group
specified with the command [8][5] + data No. [0][0]. Before reading the lower limit
values, therefore, always specify the parameter group with the command [8][5] + data
No. [0][0].
The decimal equivalent of the data No. value (hexadecimal) corresponds to the
parameter number.
8
[0] [8]
[0] [1] to [F] [F] Abbreviations of parameters
Reads the abbreviations of the parameters in the parameter group specified with the
command [8][5] + data No. [0][0]. Before reading the abbreviations, therefore, always
specify the parameter group with the command [8][5] + data No. [0][0].
The decimal equivalent of the data No. value (hexadecimal) corresponds to the
parameter number.
12
[0] [9]
[0] [1] to [F] [F] Write enable/disable of parameters
Reads write enable/disable of the parameters in the parameter group specified with
the command [8][5] + data No. [0][0]. Before reading write enable/disable, therefore,
always specify the parameter group with the command [8][5] + data No. [0][0].
0000: Write enabled
0001: Write disabled
4
(3) External I/O signals (Command [1][2])
Command
Data No.
Description
Frame Length
[0] [0]
Input device status
[4] [0]
External input pin status
[6] [0]
Status of input device turned ON by communication
[8] [0]
Output device status
[1] [2]
[C] [0]
External output pin status
8
Содержание MELSERVO MR-J3 A Series
Страница 15: ...A 14 MEMO ...
Страница 225: ...7 12 7 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 241: ...8 16 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 251: ...9 10 9 TROUBLESHOOTING MEMO ...
Страница 263: ...10 12 10 OUTLINE DRAWINGS MEMO ...