6 - 12
6. DISPLAY AND OPERATION SECTIONS
(2) Signed 6-digit or more parameter
The following example gives the operation procedure to change the electronic gear numerator (parameter
No. PA06) to "123456".
Setting of lower 4 digits
The screen flickers.
Enter the setting.
Setting of upper 1 digits
Press SET once.
Press MODE once.
Press SET once.
Press UP or DOWN to
change the setting.
Press SET once.
Press MODE once.
Press MODE three times. Press UP or DOWN to choose parameter No. PA06.
(Note)
Note. The example assumes that the status display screen that appears at power-on has been set to the servo motor speed
in parameter No. PC36.