1 - 24
1. FUNCTIONS AND CONFIGURATION
(3) MR-J3-200A MR-J3-350A
Line noise filter
(FR-BSF01)
(Note4)
power supply
Magnetic
contactor
(MC)
No-fuse breaker
(NFB) or fuse
Regenerative
option
P
C
L
21
(Note2)
Power factor
improving DC
reactor
(FR-BEL)
P
1
P
2
U V
W
Servo amplifier
CN5
CN3
Analog monitor
CN2
CN4
CN1
Junction terminal block
CN6
MR Configurator
Personal
computer
Servo motor
(Note1)
Battery unit
MR-J3BAT
L
3
(Note2)
L
11
L
2
L
1
(Note3)
R S T
Note 1. The battery unit(option) is used for the absolute position detection system in the position control mode.
2. The AC reactor can also be used. In this case, the DC reactor cannot be used. When not using DC reactor, short P
1
-P
2
.
3. For MR-J3-350A, use FR-BLF.
4. For the specification of power supply, refer to section 1.3.