2 - 2
2. INSTALLATION
(b) Installation of two or more servo amplifiers
POINT
Mounting closely is available for a combination of servo amplifiers of 3.5kW or
less in 200V or 100V class.
Leave a large clearance between the top of the servo amplifier and the internal surface of the control
box, and install a fan to prevent the internal temperature of the control box from exceeding the
environmental conditions.
When installing the servo amplifiers closely, leave a clearance of 1mm between the adjacent servo
amplifiers in consideration of mounting tolerances.
In this case, make circumference temperature into 0 to 45 , or use it at 75% or a smaller effective load ratio.
40mm or more
Control box
100mm or more
40mm or more
10mm
or more
Control box
Leaving clearance
Mounting closely
1mm 1mm
100mm or more
30mm
or more
30mm
or more
30mm
or more
30mm
or more
(2) 11kW or more
(a) Installation of one servo amplifier
40mm or more
10mm
or more
120mm
or more
Wiring
allowance
80mm
Top
Bottom
Servo amplifier
Control box
Control box
10mm
or more
Содержание MELSERVO MR-J3 A Series
Страница 15: ...A 14 MEMO ...
Страница 225: ...7 12 7 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 241: ...8 16 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 251: ...9 10 9 TROUBLESHOOTING MEMO ...
Страница 263: ...10 12 10 OUTLINE DRAWINGS MEMO ...