3 - 18
3. SIGNALS AND WIRING
(2) MR-J3-200A MR-J3-350A
(a) Servo amplifier power supply connectors
Servo amplifier power supply connectors
CNP3
CNP1
CNP2
<Applicable cable example>
Cable finish OD: to 5mm
<Applicable cable example>
Cable finish OD: to 3.8mm
Connector for CNP2
54927-0520 (Molex)
Connector for CNP3
PC4/3-STF-7.62-CRWH
(phoenix contact)
Connector for CNP1
PC4/6-STF-7.62-CRWH
(phoenix contact)
Servo amplifier
(b) Termination of the cables
1) CNP1 CNP3
Solid wire: After the sheath has been stripped, the cable can be used as it is.
7mm
Sheath
Core
Twisted wire: Use the cable after stripping the sheath and twisting the core. At this time, take care to avoid
a short caused by the loose wires of the core and the adjacent pole. Do not solder the core as
it may cause a contact fault. Alternatively, a bar terminal may be used to put the wires
together.
Cable size
Bar terminal type
[mm
2
] AWG
For 1 cable
For 2 cables
Crimping tool
Maker
1.25/
1.5
16 AI1.5-8BK
AI-TWIN2 1.5-8BK
2.0/
2.5
14 AI2.5-8BU
AI-TWIN2 2.5-10BU
3.5 12
AI4-10GY
CRIMPFOX-ZA3 Phoenix
Contact
2) CNP2
CNP2 is the same as MR-J3-100A or smaller capacities. Refer to (1) (b) of this section.