5 - 11
5. PARAMETERS
(2) Auto tuning response (parameter No. PA09)
If the machine hunts or generates large gear sound, decrease the set value. To improve performance, e.g.
shorten the settling time, increase the set value.
Setting Response
Guideline for Machine
Resonance Frequency [Hz]
Setting
Response
Guideline for Machine
Resonance Frequency [Hz]
1
Low
response 10.0
17
Low
response 67.1
2 11.3
18 75.6
3 12.7
19 85.2
4 14.3
20 95.9
5 16.1
21 108.0
6 18.1
22 121.7
7 20.4
23 137.1
8 23.0
24 154.4
9 25.9
25 173.9
10 29.2
26 195.9
11 32.9
27 220.6
12 37.0
28 248.5
13 41.7
29 279.9
14 47.0
30 315.3
15
52.9
31
355.1
16
Middle response
59.6
32
Middle response
400.0
5.1.10 In-position range
Parameter Control
Mode
No. Symbol
Name
Initial
Value
Unit
Setting
Range Position Speed Torque
PA10 INP In-position
range
100 pulse
0 to
65535
Set the range, where In position (INP) is output, in the command pulse unit before calculation of the electronic
gear. With the setting of parameter No. PC24, the range can be changed to the encoder output pulse unit.
Servo motor Droop pulse
In-position range [pulse]
Command pulse
Command pulse
Droop pulse
In position (INP)
ON
OFF