7 - 7
7. GENERAL GAIN ADJUSTMENT
7.3 Manual mode 1 (simple manual adjustment)
If you are not satisfied with the adjustment of auto tuning, you can make simple manual adjustment with three
parameters.
POINT
If machine resonance occurs, filter tuning mode (parameter No. PB01) or machine
resonance suppression filter (parameter No. PB13 to PB16) may be used to
suppress machine resonance. (Refer to section 8.3.)
(1) For speed control
(a) Parameters
The following parameters are used for gain adjustment:
Parameter No.
Abbreviation
Name
PB06
GD2
Ratio of load inertia moment to servo motor inertia moment
PB07 PG1
Model
loop
gain
PB09 VG2
Speed
loop
gain
PB10 VIC
Speed
integral
compensation
(b) Adjustment procedure
Step Operation
Description
1
Brief-adjust with auto tuning. Refer to section 7.2.3.
2
Change the setting of auto tuning to the manual mode (Parameter
No.PA08: 0003).
3
Set an estimated value to the ratio of load inertia moment to servo motor
inertia moment. (If the estimate value with auto tuning is correct, setting
change is not required.)
4
Set a slightly smaller value to the model loop gain.
Set a slightly larger value to the speed integral compensation.
5
Increase the speed loop gain within the vibration- and unusual noise-free
range, and return slightly if vibration takes place.
Increase the speed loop gain.
6
Decrease the speed integral compensation within the vibration-free range,
and return slightly if vibration takes place.
Decrease the time constant of the speed
integral compensation.
7
Increase the model loop gain, and return slightly if overshooting takes
place.
Increase the model loop gain.
8
If the gains cannot be increased due to mechanical system resonance or
the like and the desired response cannot be achieved, response may be
increased by suppressing resonance with filter tuning mode or machine
resonance suppression filter and then executing steps 2 and 3.
Suppression of machine resonance.
Refer to section 8.2, 8.3.
9
While checking the settling characteristic and rotational status, fine-adjust
each gain.