5 - 50
5. PARAMETERS
Control Mode
No. Symbol
Name
and
Function
Initial
Value
Unit
Setting
Range Position Speed Torque
PD25
0
PD26
0
PD27
0
PD28
0
PD29
0
PD30
For manufacturer setting
Do not change this value by any means.
0
5.4.3 Using forward/reverse rotation stroke end to change the stopping pattern
The stopping pattern is factory-set to make a sudden stop when the forward/reverse rotation stroke end is
made valid. A slow stop can be made by changing the parameter No. PD20 value.
Parameter No. PD20 Setting
Stopping method
0
(initial value)
Sudden stop
Position control mode
: Motor stops with droop pulses cleared.
Speed control mode
: Motor stops at deceleration time constant of zero.
1
Slow stop
Position control mode
: The motor is decelerated to a stop in accordance with the
parameter No. PB03 value.
Speed control mode
: The motor is decelerated to a stop in accordance with the
parameter No. PC02 value.