5 - 10
5. PARAMETERS
5.1.9 Auto tuning
Parameter Control
Mode
No. Symbol
Name
Initial
Value
Unit
Setting
Range Position Speed Torque
PA08
ATU Auto tuning mode
0001h
Refer to
the text.
PA09
RSP Auto tuning response
12
1 to 32
Make gain adjustment using auto tuning. Refer to section 7.2 for details.
(1) Auto tuning mode (parameter No. PA08)
Select the gain adjustment mode.
Gain adjustment mode setting
2
3
1
Setting
0
Manual mode
Automatically set parameter No. (Note)
Gain adjustment mode
Interpolation mode
Auto tuning mode 1
Auto tuning mode 2
PB06 PB08 PB09 PB10
Parameter No. PA08
PB06 PB07 PB08 PB09 PB10
PB07 PB08 PB09 PB10
0 0 0
Note. The parameters have the following names.
Parameter No.
Name
PB06
Ratio of load inertia moment to servo motor inertia moment
PB07
Model loop gain
PB08 Position
loop
gain
PB09
Speed loop gain
PB10
Speed integral compensation
Содержание MELSERVO MR-J3 A Series
Страница 15: ...A 14 MEMO ...
Страница 225: ...7 12 7 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 241: ...8 16 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 251: ...9 10 9 TROUBLESHOOTING MEMO ...
Страница 263: ...10 12 10 OUTLINE DRAWINGS MEMO ...