12.1.2 Encoder cable/connector sets
(1) MR-J3ENCBL M-A1-L/H MR-J3ENCBL M-A2-L/H
These cables are encoder cables for the HF-MP HF-KP series servo motors. The numerals in the Cable
Length field of the table are the symbols entered in the part of the cable model. The cables of the lengths
with the symbols are available.
Cable Length
Cable Model
0.3m 2m 5m 10m 20m 30m 40m 50m
Protective
Structure
Flex Life
Application
MR-J3ENCBL
M-A1-L
2 5
10 IP65
Standard
MR-J3ENCBL
M-A1-H
2 5
10 IP65
Long
flex
For HF-MP
HF-KP
servo motor
Load side lead
MR-J3ENCBL
M-A2-L
2 5
10 IP65
Standard
MR-J3ENCBL
M-A2-H
2 5
10 IP65
Long
flex
For HF-MP
HF-KP
servo motor
Opposite-to-load
side lead
(a) Connection of servo amplifier and servo motor
Servo amplifier
2)
1)
Servo motor
HF-MP
HF-KP
MR-J3ENCBL M-A2-L
MR-J3ENCBL M-A2-H
CN2
2)
1)
Servo motor
HF-MP
HF-KP
MR-J3ENCBL M-A1-L
MR-J3ENCBL M-A1-H
or
Cable Model
1) For CN2 Connector
2) For Encoder Connector
MR-J3ENCBL M-A1-L Receptacle: 36210-0100PL
Shell kit: 536310-3200-008
(3M)
Connector
set:
54599-1019
(Molex)
MR-J3ENCBL M-A1-H
MR-J3ENCBL M-A2-L
1
3
7
9
4
2
8
6
10
5
(Note) Signal layout
View seen from wiring side.
or
4
MRR
2
LG
8
6
1
P5
5
10
3
MR
7
9
BAT
(Note) Signal layout
View seen from wiring side.
MRR
LG
P5
MR
BAT
Connector: 1674320-1
Crimping tool for ground clip:
1596970-1
Crimping tool for receptacle
contact: 1596847
(Tyco Electronics)
9
SHD
7
5
MR
3
P5
1
8
6
P5G
4
MRR
2
BAT
View seen from wiring side.
(Note) Signal layout
MR-J3ENCBL M-A2-H
Note. Keep open the pins shown with
. Especially, pin 10 is provided
for manufacturer adjustment. If it is connected with any other pin,
the servo amplifier cannot operate normally.
Note. Keep open the pin shown