14 - 46
14. ABSOLUTE POSITION DETECTION SYSTEM
14.8.3 MELSEC QD75
(1) Connection diagram
0
1
2
3
4
5
7
COM
8
9
A
B
C
D
E
F
COM
NC
NC
6
0
1
2
3
4
5
7
6
8
9
A
B
QY40
QX40
Q02HCPU
Q62P
INPUT
AC100/200
COM1
COM2
JOG
JOG
(Note 2)
RA2
SD
LG
NP
NG
PP
PG
LZR
LZ
RD
INP
CR
DOCOM
49
22
41
47
8
9
11
10
36
35
30
15
17
18
19
RES
ABSR
SON
ABSM
22
23
25
48
ALM
ABSB0
ABSB1
42
EMG
43
LSP
44
LSN
20
46
DOCOM
DICOM
ABST
24
24G
FG
LG
600mA
CN1
PULSE-
R
PULSE-
F
PGO
DOG
STOP
RDY
18
17
16
15
10
9
11
4
3
QD75
FLS
1
RLS
2
CHG
5
6
7
12
13
CLEAR
14
Power
supply
Alarm reset
Emergency stop
Servo-on
Home position return
Operation mode I
Operation mode II
Position start
Position stop
COMMON
COMMON
COMMON
COMMON
(Note 2)
(Note 1)
Proximity signal
(Note 5)
Servo ready Positioning completion
Servo alarm
ABS communication error
ABS checksum error
Electromagnetic
brake output
(Note 4)
Servo-on
ABS transfer mode
ABS request
Alarm reset
(Note 3)
I
II
OFF OFF
OFF
ON
ON
OFF
ON
ON
JOG
Operation
mode
Operating
status
Home
position
return
Positioning
Upper limit
Lower limit
ABS transmission data bit 1/zero speed
ABS transmission data ready/Torque limiting
Trouble
ABS transmission data bit 0/Positioning completion
Servo amplifier
Plate
Содержание MELSERVO MR-J3 A Series
Страница 15: ...A 14 MEMO ...
Страница 225: ...7 12 7 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 241: ...8 16 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 251: ...9 10 9 TROUBLESHOOTING MEMO ...
Страница 263: ...10 12 10 OUTLINE DRAWINGS MEMO ...