16.3 GOT Side Settings
16 - 5
ROB
O
T CONTROLLER CONNE
CTION
16
16.3.4
Ethernet setting
*1
Selected from [CRnD-700] and [CR800] for [Controller Type].
*2
Each of [GOT Station] set in the communication detail setting and [Station] set in the Ethernet setting must be set to different
station numbers.
➠
16.3.2 Communication detail settings
POINT
POINT
POINT
(1) Example of [Ethernet]
For examples of [Ethernet], refer to the following.
➠
16.4 Robot controller Side Settings
(2) Communication interface setting by Utility
The communication interface setting can be changed on the Utility's [Communication
Settings] after writing [Controller Setting] of project data.
For details on the Utility, refer to the following manual.
➠
GOT2000 Series User's Manual (Utility)
(3) Precedence in communication settings
When settings are made by GT Designer3 or the Utility, the latest setting is effective.
Item
Description
Range
Host
The host is displayed. (The host is indicated with an asterisk (*))
―
N/W No.
Set the network No. of the connected Ethernet module. (Default: blank)
1 to 239
PLC No.
*2
Set the station No. of the connected Ethernet module. (Default: blank)
1 to 64
Unit Type
*1
Set the type of the connected Ethernet module.
CRnD-700, CR800
CRnD-700, CR800
IP address
Set the IP address of the connected Ethernet module. (Default: blank)
0.0.0.0 to 255.255.255.255
Port No./Communication
The port No. and communication can be set differs depending on the [Unit Type].
<CR800>
• When the port No. is [5006], the communication is [UDP (fixed)].
• When the port No. is [5007], the communication is [TCP (fixed)].
<CRnD-700>
• Port No. can be set only [5001], communication is [UDP (fixed)].
Содержание GOT2000 Series
Страница 2: ......
Страница 84: ......
Страница 432: ...6 58 6 6 Precautions ...
Страница 578: ...9 54 9 6 Precautions ...
Страница 726: ...12 84 12 5 Precautions ...
Страница 756: ......
Страница 822: ...14 66 14 4 Device Range that Can Be Set ...
Страница 918: ...15 96 15 7 Precautions ...
Страница 930: ...16 12 16 6 Precautions ...
Страница 963: ...MULTIPLE GOT CONNECTIONS 19 GOT MULTI DROP CONNECTION 19 1 20 MULTIPLE GT21 CONNECTION FUNCTION 20 1 ...
Страница 964: ......
Страница 1002: ...19 38 19 7 Precautions ...
Страница 1022: ...20 20 20 5 Precautions ...
Страница 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Страница 1024: ......
Страница 1047: ...21 3 GOT Side Settings 21 23 21 MULTI CHANNEL FUNCTION Example Setting example for Ethernet connection 4 channels ...
Страница 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Страница 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Страница 1056: ......
Страница 1223: ......