22.4 System Configuration
22 - 41
22
FA TRANSP
ARE
NT FU
NCTION
■2.
When connecting the GOT and the personal computer by Ethernet
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver, or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standards.
A cross cable is available for connecting the GOT to the Ethernet module.
*2
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*3
LCPU is not applicable to the bus connection.
PLC
GOT
Connection cable
*1
Maximum
segment
length
*2
Personal
computer
Number of
connectable
equipment
Connection type
Model
Interface
Cable model
Software
For the system configuration between the
GOT and PLC, refer to the following.
➠
*5
- (Built into
GOT) or
GT25-
J71E71-
100
Twisted pair cable
• 10BASE-T
Shielded twisted pair cable
(STP) or unshielded twisted pair
cable (UTP): Category 3, 4, and
5
• 100BASE-TX
Shielded twisted pair cable
(STP): Category 5 and 5e
100m
GX Works2
1 personal
computer
for 1 GOT
For the system configuration between the
GOT and PLC, refer to the following.
➠
SERIAL COMMUNICATION
CONNECTION
*5
- (Built into
GOT) or
GT25-
J71E71-
100
Twisted pair cable
• 10BASE-T
Shielded twisted pair cable
(STP) or unshielded twisted pair
cable (UTP): Category 3, 4, and
5
• 100BASE-TX
Shielded twisted pair cable
(STP): Category 5 and 5e
100m
GX Works3
MX Component
MX Sheet
1 personal
computer
for 1 GOT
For the system configuration between the
GOT and PLC, refer to the following.
➠
CC-Link IE CONTROLLER
NETWORK CONNECTION
➠
CC-Link IE FIELD NETWORK
CONNECTION
*5*6
- (Built into
GOT) or
GT25-
J71E71-
100
Twisted pair cable
• 10BASE-T
Shielded twisted pair cable
(STP) or unshielded twisted pair
cable (UTP): Category 3, 4, and
5
• 100BASE-TX
Shielded twisted pair cable
(STP): Category 5 and 5e
100m
GX Works3
GX Works2
1 personal
computer
for 1 GOT
For the system configuration between the
GOT and PLC, refer to the following.
➠
➠
*5
- (Built into
GOT) or
GT25-
J71E71-
100
Twisted pair cable
• 10BASE-T
Shielded twisted pair cable
(STP) or unshielded twisted pair
cable (UTP): Category 3, 4, and
5
• 100BASE-TX
Shielded twisted pair cable
(STP): Category 5 and 5e
100m
GX Works2
Setting/
Monitoring tool
for C Controller
module
1 personal
computer
for 1 GOT
For the system configuration between the
GOT and PLC, refer to the following.
➠
*3
*5*6
GOT
PC
PLC
Varies according to
the connection type.
Connection cable
Connection type
dependant
Communication driver
Содержание GOT2000 Series
Страница 2: ......
Страница 84: ......
Страница 432: ...6 58 6 6 Precautions ...
Страница 578: ...9 54 9 6 Precautions ...
Страница 726: ...12 84 12 5 Precautions ...
Страница 756: ......
Страница 822: ...14 66 14 4 Device Range that Can Be Set ...
Страница 918: ...15 96 15 7 Precautions ...
Страница 930: ...16 12 16 6 Precautions ...
Страница 963: ...MULTIPLE GOT CONNECTIONS 19 GOT MULTI DROP CONNECTION 19 1 20 MULTIPLE GT21 CONNECTION FUNCTION 20 1 ...
Страница 964: ......
Страница 1002: ...19 38 19 7 Precautions ...
Страница 1022: ...20 20 20 5 Precautions ...
Страница 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Страница 1024: ......
Страница 1047: ...21 3 GOT Side Settings 21 23 21 MULTI CHANNEL FUNCTION Example Setting example for Ethernet connection 4 channels ...
Страница 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Страница 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Страница 1056: ......
Страница 1223: ......