1 - 18
1.1 Setting the Communication Interface
■2.
Setting item
The following describes the setting items for the standard I/F setting and extension I/F setting.
For the detailed explanations, refer to the following manual.
➠
GT Designer3 (GOT2000) Screen Design Manual
Item
Description
Standard I/F setting
Set channel No. and drivers to the GOT standard interfaces.
CH No.
Set the CH No. according to the intended purpose.
0: Not used
1 to 4: Used for connecting a controller of channel No. 1 to 4 set in Setting connected equipment (Channel
setting)
5 to 8: Used for barcode function, RFID function, remote personal computer operation function (serial)
A: Used for the report function (with a serial printer), hard copy function (with a serial printer).
Driver
Set the driver for the device to be connected.
• Each communication driver suitable to the channel numbers
• Each communication driver for connected devices
Detail Setting
Set the detailed settings for the communication driver.
➠
Refer to each chapter of the equipment to be connected to the GOT.
I/F-1,I/F-2,I/F-3
The communication type of the GOT standard interface is displayed.
RS232 Setting
To validate the 5V power supply function in RS232, mark the [Enable the 5V power supply] checkbox.
The RS232 setting is invalid when the CH No. of [I/F-1: RS232] is [9].
GT21 is not supported.
Ethernet connection
setting
Set the channel number and the communication driver to the Ethernet interface with a built-in GOT.
CH No.
Set the CH No. according to the intended purpose.
0: Not used
1 to 4: Used for connecting a controller of channel No. 1 to 4 set in Setting connected equipment (Channel
setting)
9: Used for connecting Host (PC) or Ethernet download
A: Used for the remote personal computer operation function (Ethernet), VNC server function, gateway
function, and MES interface function.
Multi: Used for multi-channel Ethernet connection
Driver
Set the driver for the device to be connected.
• Each communication driver suitable to the channel numbers
• Each communication driver for connected devices
Detail Setting
Set the detailed settings for the communication driver.
➠
Refer to each chapter of the equipment to be connected to the GOT.
When the GT21 series is
selected in the GOT type setting
Содержание GOT2000 Series
Страница 2: ......
Страница 84: ......
Страница 432: ...6 58 6 6 Precautions ...
Страница 578: ...9 54 9 6 Precautions ...
Страница 726: ...12 84 12 5 Precautions ...
Страница 756: ......
Страница 822: ...14 66 14 4 Device Range that Can Be Set ...
Страница 918: ...15 96 15 7 Precautions ...
Страница 930: ...16 12 16 6 Precautions ...
Страница 963: ...MULTIPLE GOT CONNECTIONS 19 GOT MULTI DROP CONNECTION 19 1 20 MULTIPLE GT21 CONNECTION FUNCTION 20 1 ...
Страница 964: ......
Страница 1002: ...19 38 19 7 Precautions ...
Страница 1022: ...20 20 20 5 Precautions ...
Страница 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Страница 1024: ......
Страница 1047: ...21 3 GOT Side Settings 21 23 21 MULTI CHANNEL FUNCTION Example Setting example for Ethernet connection 4 channels ...
Страница 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Страница 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Страница 1056: ......
Страница 1223: ......