Communication detail settings
Make the settings according to the usage environment.
*1
For details, refer to the following manual.
➠
CC-Link IE Field Network Master/Local Module User's Manual
*2
This range is effective when collecting a large amount of data (such as logging and recipe function) on other than the monitor
screen.
However, the range may affect the sequence scan time when connecting to Q00UJ/Q00U/Q01U/Q02UCPU.
If you want to avoid the influence on the sequence scan time, do not set [High(Normal)].
(This setting hardly affects QCPUs other than the above.)
*3
Set this range if you want to avoid the influence on the sequence scan time further than the [Middle] setting when connecting to
Q00UJ/Q00U/Q01U/Q02UCPU.
However, the monitor speed may be reduced.
*4
When using a global label, to read or write more than 235 two-byte characters, set the [Monitor speed] to [High (Standard)] or
[Middle].
If [Monitor speed] is set to [Low], a system error occurs when reading or writing.
For details, refer to the following manual.
➠
GT Designer3 (GOT2000) Screen Design Manual
Item
Description
Range
Network Type
*4
Set the network Type
• CC IE Field
Network No.
Set the network No. of the GOT.
(Default: 1)
1 to 239
Station No.
Set the station No. of the GOT.
(Default: 1)
1 to 120
Group No.
-
0 (fixed)
Mode Setting
Set the operation mode of the GOT.
(Default:
Online (auto. reconnection))
• Online
• Offline
• H/W test
*1
• Self-loopback test
*1
Tramsmission Speed
-
1 Gbps (fixed)
Reflesh Interval
Set the number of refreshes to secure the send/receive data in station units during communication.
(Default: 25ms)
1 to 1000ms
Input for Error Station
Set the hold/clear of input from the station where the data link is faulty due to some reason such as
turning the power OFF.
(Default: Clear)
Clear/Hold
Retry
Set the number of retries to be performed when a communication timeout occurs.
When receiving no response after retries, the communication times out.
(Default: 3times)
0 to 5times
Timeout
Time
Set the time period for a communication to time out.
(Default: 3sec)
3 to 90sec
Delay Time
Set the delay time for reducing the load of the network/destination PLC.
(Default: 0ms)
0 to 300ms
Monitor Speed
*4
Set the monitor speed for the CC-Link IE field network.
This setting is not valid in all systems.
(Default: High(Normal))
High(Normal)
*2
/
Middle/Low
*3
Servo axis switching GD
device head No.
Set the servo axis switching GD device head No.
(Default: 10)
For details, refer to the following POINT.
➠
(5) Indirect specification of the servo axis No.
0 to 65520
Содержание GOT2000 Series
Страница 2: ......
Страница 84: ......
Страница 432: ...6 58 6 6 Precautions ...
Страница 578: ...9 54 9 6 Precautions ...
Страница 726: ...12 84 12 5 Precautions ...
Страница 756: ......
Страница 822: ...14 66 14 4 Device Range that Can Be Set ...
Страница 918: ...15 96 15 7 Precautions ...
Страница 930: ...16 12 16 6 Precautions ...
Страница 963: ...MULTIPLE GOT CONNECTIONS 19 GOT MULTI DROP CONNECTION 19 1 20 MULTIPLE GT21 CONNECTION FUNCTION 20 1 ...
Страница 964: ......
Страница 1002: ...19 38 19 7 Precautions ...
Страница 1022: ...20 20 20 5 Precautions ...
Страница 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Страница 1024: ......
Страница 1047: ...21 3 GOT Side Settings 21 23 21 MULTI CHANNEL FUNCTION Example Setting example for Ethernet connection 4 channels ...
Страница 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Страница 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Страница 1056: ......
Страница 1223: ......