13 - 18
13.5 PLC Side Settings
13.5 PLC Side Settings
13.5.1
Connecting AJ65BT-G4-S3
This section describes the settings of the GOT and peripheral connection module in the following case of the system
configuration.
POINT
POINT
POINT
(1) Peripheral connection module
For details of the peripheral connection module, refer to the following manual.
➠
Peripheral Connection Module Type AJ65BT-G4-S3 User's Manual (detail volume)
(2) CC-Link module
For details of the CC-Link module, refer to the following manual.
➠
CC-Link System Master/Local Module User's Manual QJ61BT11N
➠
MELSEC-L CC-Link System Master/Local Module User's Manual
(3) CC-Link function built-in CPU
For details on the CC-Link function built-in CPU, refer to the following manual.
➠
MELSEC-L CC-Link System Master/Local Module User's Manual
■1.
System configuration
*1
The Start I/O No. of the CC-Link module is set to "0"
■2.
Switch setting of peripheral connection module
Set the station number setting switch, data link transmission speed setting switch, and operation setting DIP switch.
Model
Reference
Peripheral connection module
AJ65BT-G4-S3
AJ65BT-R2N
<CC-Link module>
*1
Station type
Station No.
Mode
All connect count
Transmission speed
<AJ65BT-G4-S3>
Station type
Station No.
Number of stations occupied
Transmission speed
<GOT>Setting example
Transmission speed: 9600bps
: Master station
: Station No. 0
: Remote net (Ver.1 mode)
: 1
: Intelligent device station
: Station No. 1
: Exclusive station 1
: 156kbps
: 156kbps
Setting example
Setting example
(2)
(1)
(3)
B RATE
STATION NO.
x 10
x 1
SW
1
8
2 3 4 5 6 7
ON
RESET
PW
RUN
L RUN
SD
RD
L ERR.
MITSUBISHI
A
J65BT-G4-S3
RS-422
5
0
6
9
2
7
8
1
3
4
5
0
6
2
1
3
4
0
2
1
3
4
SW1
MODE
QnA
A
non-used
Q
SW6
OFF
OFF
ON
ON
OFF
OFF
ON
ON
Содержание GOT2000 Series
Страница 2: ......
Страница 84: ......
Страница 432: ...6 58 6 6 Precautions ...
Страница 578: ...9 54 9 6 Precautions ...
Страница 726: ...12 84 12 5 Precautions ...
Страница 756: ......
Страница 822: ...14 66 14 4 Device Range that Can Be Set ...
Страница 918: ...15 96 15 7 Precautions ...
Страница 930: ...16 12 16 6 Precautions ...
Страница 963: ...MULTIPLE GOT CONNECTIONS 19 GOT MULTI DROP CONNECTION 19 1 20 MULTIPLE GT21 CONNECTION FUNCTION 20 1 ...
Страница 964: ......
Страница 1002: ...19 38 19 7 Precautions ...
Страница 1022: ...20 20 20 5 Precautions ...
Страница 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Страница 1024: ......
Страница 1047: ...21 3 GOT Side Settings 21 23 21 MULTI CHANNEL FUNCTION Example Setting example for Ethernet connection 4 channels ...
Страница 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Страница 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Страница 1056: ......
Страница 1223: ......