10 - 26
10.4 PLC Side Setting
10.4.3
Connecting to MELSEC-Q/L series
■1.
System configuration1 (Network Type: CC IE Control)
*1
The CC-Link IE Controller Network module is mounted on slot 0 of the base unit.
The start I/O No. of the CC-Link IE Controller Network module is set at [0].
POINT
POINT
POINT
When connecting to Q170MCPU or Q170MSCPU(-S1)
When connected to Q170MCPU or Q170MSCPU(-S1), the start I/O No. of the CC-Link IE
Controller Network module is set to "70".
■2.
System configuration2 (Network Type: CC IE Control extended mode)
*1
The CC-Link IE Controller Network module is mounted on slot 0 of the base unit.
The start I/O No. of the CC-Link IE Controller Network module is set at [0].
<CC-Link IE Controller Network module> *
1
(Use the default value for settings other than the following.)
Station No.
: 1
Mode
: Online
Network type
: CC IE Control (Control station)
Network No.
: 1
Total stations
: 2
Network range assignment :
CC-Link IE Controller Network
<GOT>
(Use the default value for settings other
than the following.)
LB0000
H
to LB00FF
H
LW00000
H
to LW000FF
H
Network type
: CC IE Control
Network No.
: 1
Station No.
: 2
Made Setting : Online (auto,reconnection)
Network range assignment :
Monitor Speed : High
LB0100
H
to LB01FF
H
LW00100
H
to LW001FF
H
<CC-Link IE Controller Network module> *
1
(Use the default value for settings other than the following.)
Station No.
: 1
Mode
: Online
Network type
: CC IE Control extended mode
(Control station)
Network No.
: 1
Total stations
: 2
Network range assignment :
CC-Link IE Controller Network
<GOT>
(Use the default value for settings other
than the following.)
LB0000
H
to LB00FF
H
LW00000
H
to LW000FF
H
Network type
: CC IE Control extended mode
Network No.
: 1
Station No.
: 2
Made Setting : Online (auto,reconnection)
Network range assignment :
Monitor Speed : High
LB0100
H
to LB01FF
H
LW00100
H
to LW001FF
H
Содержание GOT2000 Series
Страница 2: ......
Страница 84: ......
Страница 432: ...6 58 6 6 Precautions ...
Страница 578: ...9 54 9 6 Precautions ...
Страница 726: ...12 84 12 5 Precautions ...
Страница 756: ......
Страница 822: ...14 66 14 4 Device Range that Can Be Set ...
Страница 918: ...15 96 15 7 Precautions ...
Страница 930: ...16 12 16 6 Precautions ...
Страница 963: ...MULTIPLE GOT CONNECTIONS 19 GOT MULTI DROP CONNECTION 19 1 20 MULTIPLE GT21 CONNECTION FUNCTION 20 1 ...
Страница 964: ......
Страница 1002: ...19 38 19 7 Precautions ...
Страница 1022: ...20 20 20 5 Precautions ...
Страница 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Страница 1024: ......
Страница 1047: ...21 3 GOT Side Settings 21 23 21 MULTI CHANNEL FUNCTION Example Setting example for Ethernet connection 4 channels ...
Страница 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Страница 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Страница 1056: ......
Страница 1223: ......