A-6
In compliance with the requirements in clause 4.2.9.14 of ANSI/AAMI EC 13:2002
ESU noise suppression
Based on the test method in clause 5.2.9.14 of EC 13, use ECG lead wires which are
in compliance with AAMI. Compared with ECG baseline, the noise of peak to peak
value ≤2 mV.
Pace Pulse
Pace pulse markers
Pace pulses meeting the following conditions are labelled with a PACE marker:
Amplitude:
Width:
Rise time:
±2 to ±700 mV
0.1 to 2 ms
10 to 100 µs
Pace pulse rejection
When tested in accordance with the ANSI/AAMI EC13: Sections 4.1.4.1 and 4.1.4.3,
the heart rate meter rejects all pulses meeting the following conditions.
Amplitude:
Width:
Rise time:
±2 to ±700 mV
0.1 to 2 ms
10 to 100 µs
Pacer pulse detector rejection of fast
ECG signals
2.9 V/s RTI when measured in accordance with ANSI/AAMI EC13: Section 4.1.4.3.
HR
Measurement range
3-, 5-lead ECG
15 to 350 bpm
Resolution
1 bpm
Accuracy
±1 bpm or ±1%, whichever is greater.
Sensitivity
200μV (lead II)
HR averaging method
In compliance with the requirements in Clause 4.1.2.1 d)of ANSI/AAMI EC13, the
following method is used:
If the last 3 consecutive RR intervals are greater than 1200 ms, the 4 most recent
RR intervals are averaged to compute the HR. Otherwise, heart rate is computed
by subtracting the maximum and minimum ones from the most recent 12 RR
intervals and then averaging them.
The HR value displayed on the monitor screen is updated every second.
Response to irregular rhythm
In compliance with the requirements in Clause 4.1.2.1 e)of ANSI/AAMI EC13, the
heart rate after 20 seconds of stabilization is displayed as follows:
Ventricular bigeminy (3a): 80±1 bpm
Slow alternating ventricular bigeminy (3b): 60±1 bpm
Rapid alternating ventricular bigeminy (3c): 120±1 bpm
Bidirectional systoles (3d): 90±2 bpm
Response time to heart rate change
Meets the requirements of ANSI/AAMI EC13: Section 4.1.2.1 f).
From 80 to 120 bpm: less than 11 s
From 80 to 40 bpm: less than 11 s
Time to alarm for tachycardia
Meets the requirements of ANSI/AAMI EC13: section 4.1.2.1 g).
Содержание iMEC8 Vet
Страница 1: ...iMEC8 Vet Portable Multi Parameter Veterinary Monitor Operator s Manual ...
Страница 2: ......
Страница 16: ...X F 1 Symbols F 1 F 2 Abbreviations F 2 ...
Страница 54: ...6 6 FOR YOUR NOTES ...
Страница 94: ...11 8 FOR YOUR NOTES ...
Страница 170: ...A 14 FOR YOUR NOTES ...
Страница 176: ...B 6 FOR YOUR NOTES ...
Страница 201: ......
Страница 202: ...PN 046 008143 00 3 0 ...