Installation
2 - 43
Standard Turntable Power Washer v. 4.0
The MART Corporation
Refer to the startup procedure in the burner vendor's manual.
NOTE:
At this point, all manual gas valves should be closed.
4. Verify that the washer reservoir is filled to the factory pre-set level with water.
The burner cannot fire until correct water level is reached.
5. Set the temperature controller, according to the following table. After you set
the controller, the burner will come on and attempt to fire. (The controller is
labeled inside the electrical control panel.)
NOTE:
The set-point on the
controller can differ from the actual temperature.
At this point you should follow the startup procedure in the burner vendor's
manual.
Note: Due to various installation variables, it may be necessary to adjust
operating parameters to obtain consistent burner performance.
Maximum Actual Operating
Temperature
Altitude in Feet
Temperature
°
F
0
- 2000
190
°
F (88
°
C)
2000
- 4000
185
°
F (85
°
C)
4000
- 5000
180
°
F (82
°
C)
5000 and above
call MART
WARNING! Do NOT exceed recommended settings, or
serious damage can occur in the wash pump (cavitation).
Fig. 2 - 20: Maximum Operating Temperature
6. Take a sample of flue gases where the flue pipe attaches to the roof of the
washer cabinet. There is a port at the flue damper for this measurement.
WARNING! A certified burner technician, using flue-gas-
analyzing equipment must make any adjustments to the
burner.
7. Verify that the fuel/air mixture is correct, by comparing your readings with the
following table. Refer also to your vendor-supplied burner manual.
WARNING! Proper air/fuel mixture is imperative for efficient
operation and safety.
Содержание Cyclone 30 Series
Страница 250: ...Options 7 71 Standard Turntable Power Washer v 4 0 The MART Corporation Fig 7 36 Rack and Fixture Set...
Страница 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Страница 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Страница 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Страница 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...