Installation
2 - 39
Standard Turntable Power Washer v. 4.0
The MART Corporation
2. During the initial startup of your power washer the washer will fill itself to the
set-point water level. This water level is controlled by the position of the cam
on the float rod.
Moving the cam
down
on the float rod will
raise
the water level, while moving
the cam
up
on the float rod will
lower
the water level.
When the washer has completed filling to the set-point water level, the cam
and float limit switches should appear as shown in the following figure.
Fig. 2 - 17: Float Cam at SET-POINT Water Level
Turn
OFF
power to the washer.
Make sure the water is calm.
Remove the front reservoir cover.
Verify the water level in the machine when the cam is in relationship to the
limit switches as shown in the figure above.
Find the water-level indicator (a 3/8"-square rectangular bar) welded to the
right wall at the front of the reservoir. Refer to the following figure.
Содержание Cyclone 30 Series
Страница 250: ...Options 7 71 Standard Turntable Power Washer v 4 0 The MART Corporation Fig 7 36 Rack and Fixture Set...
Страница 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Страница 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Страница 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Страница 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...