Installation
2 - 31
Standard Turntable Power Washer v. 4.0
The MART Corporation
5.3.2.
Flue Pipe (Output)
NOTE
: A flue pipe is used ONLY for gas or oil burners.
WARNING! The flue-pipe connection must be independent of
any other pipe connection. It can not share a heating-system
pipe with any other equipment.
WARNING! Be sure that people who adjust the burner are
qualified and trained for the task. Be sure they use
appropriate flue-gas monitoring instruments for measuring
oxygen, carbon dioxide, AND CARBON MONOXIDE.
WARNING! VENTING OF EXHAUST GASES: Do NOT vent
exhaust gases into a wall, a ceiling, or a concealed space of a
building. Refer to the instructions in this chapter for correct
vent installation instructions.
Flue Pipe installation
Your MART Power Washer is capable of producing exhaust gas temperatures up to
1000 degrees F.
The gas burner flue installation must comply with all applicable local and/or national gas
codes for
materials, pipe size,
and
installation
procedures.
Note: (MART recommends a minimum of 16-gauge material for the flue pipe.)
IMPORTANT:
The flue pipe system installed on the MART Power Washer must be sized to create the
proper draft during burner firing. The draft required is
±
.25 WCI pressure at the flue-
pipe stub during burner firing.
Typical installations with an equivalent 10-50 foot flue exhaust run generally will function
properly with a flue pipe size 2” larger than the exhaust stub to obtain the required draft
pressures of
±
.25 WCI at the flue pipe stub.
The MART Corporation does not recommend the use of draft inducers or barometric
dampers in a properly designed exhaust system.
To install the flue, follow this procedure
Содержание Cyclone 30 Series
Страница 250: ...Options 7 71 Standard Turntable Power Washer v 4 0 The MART Corporation Fig 7 36 Rack and Fixture Set...
Страница 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Страница 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Страница 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Страница 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...