7 - 36
Installation, Operations, and Maintenance Manual
The MART Corporation
Standard Turntable Power Washer v.
4
.0
·
Replace belts with original manufacturer's equipment or equivalent.
·
Keep extra belts stored in a cool, dark, dry place.
6.5. Troubleshooting
This section contains tables on the following problems:
·
Squealing sounds from pump area
·
No wash cycle (no water pumped): simplex pump system
·
Poor cleaning results
or
abnormal pump noise: duplex pump system
Problem:
50 Hz electrical power -- Squealing sounds from pump
area
Check This:
Probable Cause(s)
Belt(s)
Slippage (tighten)
Worn and frayed (replace)
Sheaves
Walls worn, with resulting belt slippage (replace)
Fig. 7 - 16: Troubleshooting: 50 Hz Electrical Power -- Squealing Sounds from
Pump Area
Problem:
50 Hz electrical power -- No wash cycle (no water
pumped): simplex pump system
Check This:
Probable Cause(s)
Belt(s)
Broken (replace)
Fig. 7 - 17: Troubleshooting: 50 Hz Electrical Power -- No Wash Cycle (No Water
Pumped): Simplex Pump System
Содержание Cyclone 30 Series
Страница 250: ...Options 7 71 Standard Turntable Power Washer v 4 0 The MART Corporation Fig 7 36 Rack and Fixture Set...
Страница 295: ...MART REVISION 06 06 06 Revision 03 OWNER S MANUAL for MART VERTICAL POWER WASHER PUMP...
Страница 308: ...12 Fig 1 Main Pump Cut Away 1530 Frame Hardened Steel Throttle Bushing...
Страница 310: ...14 Fig 2 Main Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 312: ...16 Fig 3 Main Pump Cut Away 12V Frame Composite Throttle Bushing...
Страница 314: ...18 Fig 4 Boost Pump Cut Away 1530 Frame Composite Throttle Bushing...
Страница 316: ...20 Fig 4 Boost Pump Cut Away 12V Frame Composite Throttle Bushing...